2007 ASHRAE Handbook HVAC Applications Chapter14
$33.80
HVAC Applications Handbook – Chapter 14. Laboratories
Published By | Publication Date | Number of Pages |
ASHRAE | 2007 | 22 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Laboratory Types Laboratory Types Laboratory Resource Materials Laboratory Resource Materials |
2 | Hazard Assessment Hazard Assessment Design Parameters Design Parameters Internal Thermal Considerations Internal Thermal Considerations |
3 | Architectural Considerations Architectural Considerations Laboratory Exhaust and Containment Devices Laboratory Exhaust and Containment Devices Fume Hoods Fume Hoods Types of Fume Hoods Types of Fume Hoods |
4 | Fume Hood Sash Configurations Fume Hood Sash Configurations Fume Hood Performance Fume Hood Performance |
5 | Face Velocity Test Face Velocity Test |
6 | Biological Safety Cabinets Biological Safety Cabinets |
7 | Class I Cabinets Class I Cabinets Class II Cabinets Class II Cabinets |
8 | Class III Cabinets Class III Cabinets Miscellaneous Exhaust Devices Miscellaneous Exhaust Devices Laminar Flow Clean Benches Laminar Flow Clean Benches Compressed Gas Storage and Ventilation Compressed Gas Storage and Ventilation Gas Cylinder Closets Gas Cylinder Closets Gas Cylinder Cabinets Gas Cylinder Cabinets Laboratory Ventilation Laboratory Ventilation |
9 | Usage Factor Usage Factor Noise Noise Supply Air Systems Supply Air Systems Filtration Filtration Air Distribution Air Distribution Exhaust Systems Exhaust Systems |
10 | Types of Exhaust Systems Types of Exhaust Systems Ductwork Leakage Ductwork Leakage Containment Device Leakage Containment Device Leakage Materials and Construction Materials and Construction |
11 | Fire Safety for Ventilation Systems Fire Safety for Ventilation Systems |
12 | Control Control Thermal Control Thermal Control Constant Air Volume (CAV) Versus Variable Air Volume (VAV) Room Airflow Control Constant Air Volume (CAV) Versus Variable Air Volume (VAV) Room Airflow Control Room Pressure Control Room Pressure Control |
13 | Fume Hood Control Fume Hood Control Stack Heights and Air Intakes Stack Heights and Air Intakes Stack/Intake Separation Stack/Intake Separation Stack Height Stack Height Stack Height plus Momentum Stack Height plus Momentum Architectural Screens Architectural Screens Criteria for Suitable Dilution Criteria for Suitable Dilution |
14 | Adjacent Building Effects Adjacent Building Effects Applications Applications Laboratory Animal Facilities Laboratory Animal Facilities Primary Uses of Animal Housing Facilities Primary Uses of Animal Housing Facilities Regulatory Environment Regulatory Environment |
15 | Temperature and Humidity Temperature and Humidity Ventilation Ventilation Animal Heat Production Animal Heat Production Design Considerations Design Considerations |
16 | Caging Systems Caging Systems Ancillary Spaces For Animal Laboratories Ancillary Spaces For Animal Laboratories Containment Laboratories Containment Laboratories |
17 | Biosafety Level 1 Biosafety Level 1 Biosafety Level 2 Biosafety Level 2 Biosafety Level 3 Biosafety Level 3 Biosafety Level 4 Biosafety Level 4 Scale-Up Laboratories Scale-Up Laboratories |
18 | Teaching Laboratories Teaching Laboratories Clinical Laboratories Clinical Laboratories Radiochemistry Laboratories Radiochemistry Laboratories Operation and Maintenance Operation and Maintenance Energy Energy |
19 | Energy Efficiency Energy Efficiency Energy Recovery Energy Recovery Commissioning Commissioning Economics Economics |
20 | References References Bibliography Bibliography |