Shopping Cart

No products in the cart.

ASHRAE UserManual 62.1 2019

$53.63

ASHRAE Standard 62.1 User’s Manual–Based on ANSI/ASHRAE Standard 62.1-2019, Ventilation for Acceptable Indoor Air Quality

Published By Publication Date Number of Pages
ASHRAE 2019 144
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This companion guide provides detailed information on the requirements of ANSI/ASHRAE Standard 62.1-2019 and includes tables, illustrations, and examples to aid users in designing, installing, and operating systems for ventilation in buildings. Standard 62.1 User’s Manual does not reproduce the requirements of the standard but rather paraphrases and elaborates upon them. Intended to be used in conjunction with the standard, this manual provides: • Information on the intent and application of Standard 62.1 • Sample calculations and examples • Best practices for applying the principles of good indoor air quality (IAQ) and effective ventilation when designing buildings and building systems • Useful reference material • Guidance for building operations and maintenance personnel • Instructions for the user in the application of tools used for compliance with ANSI/ASHRAE Standard 62.1-2019 Also included is an exclusive link to the recently revised Web-based spreadsheets that aid in ventilation rate procedure calculations. This manual is intended for architects, engineers, manufacturers, plan examiners, field inspectors, general and specialty contractors, and operation and maintenance personnel. Standard 62.1 User’s Manual is a crucial supplement for professionals concerned with ventilation and indoor air quality. Use it alongside your copy of ANSI/ASHRAE Standard 62.1-2019.

PDF Catalog

PDF Pages PDF Title
1 Standard 62.1 User’s Manual
5 Contents
8 Figures
Tables
9 Examples
11 Preface
General Information
Audience
Addenda
Official Interpretations
12 Standard 62.1 Organization
13 Organization and Use of the User’s Manual
Data and Analysis Tools
14 Acknowledgments
15 1 Purpose
Overview (§1.1)
Regulatory Application (§1.2)
Existing Buildings (§1.3)
17 2 Scope
Spaces Covered (§2.1)
Scope of Requirements (§2.2)
Issues Covered (§2.3)
Laboratories, Healthcare, and Smoking Spaces (§2.4)
19 3 Definitions, Abbreviations, and Acronyms
Definitions
Abbreviations and Acronyms
21 4 Outdoor Air Quality
Overview
Regional Air Quality (§4.1)
22 Local Air Quality (§4.2)
23 Documentation (§4.3)
Regional Air Quality Compliance
Local Air Quality Survey Information
24 Summary
25 5 Systems and Equipment
Overview
Ventilation Air Distribution (§5.1)
Designing for Air Balancing (§5.1.1)
26 Designing for Varying Loads and Operating Conditions (§5.1.1.1)
Plenum Systems (§5.1.2)
29 Documentation (§5.1.3)
Exhaust Duct Location (§5.2)
31 Ventilation System Controls (§5.3)
Constant-Volume, Single-Zone Systems
32 Variable-Air-Volume System
33 Airstream Surfaces (§5.4)
Resistance to Mold Growth (§5.4.1)
Resistance to Erosion (§5.4.2)
34 Outdoor Air Intakes (§5.5)
Location (§5.5.1)
36 Rain Entrainment and Intrusion (§5.5.2 and §5.5.3)
37 Snow Entrainment (§5.5.4)
38 Bird Screens (§5.5.5)
Local Capture of Contaminants (§5.6)
Ozone Generating Devices (§5.7)
39 Combustion Air (§5.8)
Particulate Matter Removal (§5.9)
Maximum Indoor Air Dew Point in Mechanically Cooled Buildings (§5.10)
41 Building Exfiltration (§5.11)
Exception to the Exfiltration Requirement
44 Drain Pans (§5.12)
Drain-Pan Slope (§5.12.1)
45 Drain Outlet (§5.12.2)
Drain Seal (§5.12.3)
Pan Size (§5.12.4)
46 Finned-Tube Coils and Heat Exchangers (§5.13)
Drain Pans (§5.13.1)
47 Finned-Tube-Coil Selection for Cleaning (§5.13.2)
48 Humidifiers and Water Spray Systems (§5.14)
Water Quality (§5.14.1)
Obstructions (§5.14.2)
49 Access for Inspection, Cleaning, and Maintenance (§5.15)
Equipment Clearance (§5.15.1)
Ventilation Equipment Access (§5.15.2)
50 Air Distribution System (§5.15.3)
Building Envelope and Interior Surfaces (§5.16)
51 Building Envelope (§5.16.1)
Weather Barrier
Vapor Retarder
Caulking and Sealing
52 Soil Gases
Condensation on Interior Surfaces (§5.16.2)
Buildings with Attached Parking Garages (§5.17)
53 Air Classification and Recirculation (§5.18)
Classification (§5.18.1)
Redesignation (§5.18.2)
54 Air Cleaning (§5.18.2.1)
Transfer (§5.18.2.2)
55 Recirculation Limitations (§5.18.3)
Documentation (§5.18.4)
56 ETS Areas and ETS-Free Areas (§5.19)
58 Classification (§5.19.1)
Engineering Analysis
Pressure Differential Measurement
Airflow Measurement
59 Pressure Exception for Dwelling Units and Adjacent Properties
61 Pressure Exception for Hazardous Materials
63 Physical Separation (§5.19.3)
64 Transfer Air (§5.19.4)
Recirculation Prohibition (§5.19.5)
65 Exhaust Systems (§5.19.6)
Signage (§5.19.7)
66 Reclassification (§5.19.8)
67 6 Procedures
General (§6.1)
68 Outdoor Air Treatment (§6.1.4)
Particulate Matter (§6.1.4.1 and §6.1.4.2)
69 Ozone (§6.1.4.3)
70 Other Outdoor Contaminants (§6.1.4.4)
71 Ventilation Rate Procedure (§6.2)
Rationale for Ventilation Rate Procedure
Two Component Approach and Additivity
73 Determining Component Ventilation Rates
76 Ventilation Efficiency
79 VRP Summary
Zone Calculations (§6.2.1)
80 Determine Occupant and Building Rate Requirements (Rp and Ra) (§6.2.1.1)
Additional Requirements and Exceptions (§6.2.1.1.2 through §6.2.1.1.6)
81 Estimate the Number of Occupants in the Zone (Pz) (§6.2.1.1.7)
82 Calculate the Net Occupiable Floor Area (Az)
Calculate the Outdoor Air Required in the Breathing Zone (Vbz)
Determine the Zone Air Distribution Effectiveness (Ez) (§6.2.1.2)
Calculate the Minimum Zone Outdoor Air Rate Required at the Supply Air Outlets (Voz) (§6.2.1.3)
84 System Calculations
Single-Zone Systems (§6.2.2)
100% Outdoor Air Systems (§6.2.3)
Multiple-Zone Recirculating Systems (§6.2.4)
85 Determine Uncorrected Outdoor Airflow (Vou) (§6.2.4.1)
Determine System Ventilation Efficiency (Ev) (§6.2.4.2)
88 Calculate System Outdoor Air Intake (Vot) (§6.2.4.4)
97 Designing for Varying Operating Conditions (§6.2.5)
Variable Load Conditions (§6.2.5.1)
Short-Term Conditions (§6.2.5.2)
102 Dynamic Reset (§6.2.6)
Demand Control Ventilation (DCV) (§6.2.6.1)
103 Ventilation Efficiency (§6.2.6.2)
Outdoor Air Fraction (§6.2.6.3)
104 Indoor Air Quality (IAQ) Procedure (§6.3)
105 Compliance Requirements
106 Contaminant Sources (§6.3.1)
107 Contaminant Concentration (§6.3.2)
Perceived Indoor Air Quality (§6.3.3)
108 Design Approach (§6.3.4)
109 Combined IAQ Procedure and Ventilation Rate Procedure (§6.3.5)
Documentation (§6.3.6)
111 Natural Ventilation Procedure (§6.4)
112 Prescriptive Compliance Path (§6.4.1)
113 Engineered System Compliance Path (§6.4.2)
117 Exhaust Ventilation (§6.5)
Prescriptive Compliance Path (§6.5.1)
Performance Compliance Path (§6.5.2)
119 Design Documentation Procedures (§6.6)
120 7 Construction and System Start-Up
General
Construction Phase (§7.1)
Filters (§7.1.2)
Protection of Materials (§7.1.3)
121 Protection of Occupied Areas (§7.1.4)
Air Duct System Construction (§7.1.5)
123 System Start-Up (§7.2)
Application (§7.2.1)
New Air Handler
Limited Alterations
Air Balancing (§7.2.2)
124 Testing of Drain Pans (§7.2.3)
125 Cleanliness (§7.2.4)
Testing of Outdoor Air Dampers (§7.2.5)
System Documentation (§7.2.6)
127 8 Operations and Maintenance
General (§8.1)
Application (§8.1.1)
128 Building Alterations or Change of Use (§8.1.2)
129 Operations and Maintenance Manual (§8.2)
130 Ventilation System Operation (§8.3)
Ventilation System Maintenance (§8.4)
131 Water Intrusion (Table 8-1, item a)
132 Appendix A Dynamic Ventilation Reset Control
Overview
Demand Control Ventilation (DCV)
Fundamentals of CO2-Based DCV
136 Steady-State Assumption
Control of Single-Zone Systems with Airflow Measurement
Breathing Zone Parameters (Rp, Pz, Ra, Az)
Zone Air Distribution Effectiveness (Ez)
Activity Level
Indoor Concentration
Outdoor CO2 Concentration
137 Single-Zone DCV Control Sequence
Control of Constant-Volume Systems without Airflow Measurement
139 Control of Multiple-Zone Systems
CO2-based Dynamic Reset (CO2-based DR) Control Sequence
141 Outdoor Air Fraction/Ventilation Efficiency-Based Dynamic Reset
Zone Controls
142 Air-Handler Controls
ASHRAE UserManual 62.1 2019
$53.63