BSI PD CLC/TR 62453-61:2009:2010 Edition
$167.15
Field device tool interface (FDT) specification – Device type manager (DTM). Styleguide for common object model
Published By | Publication Date | Number of Pages |
BSI | 2010 | 38 |
IEC/TR 62453-61, which is a technical report, explains the guidelines and rules for the implementation of a Device Type Manager (DTM) with regard to the user interface and its functions. These guidelines and rules are part of the FDT specification and are intended to ensure that all users are provided with clear and consistent user interface functions and features across DTM devices in a system.
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | CONTENTS |
8 | INTRODUCTION Figures Figure 1 – Part 61 of the IEC 62453 series |
9 | 1 Scope 2 Normative references 3 Terms, definitions, symbols, abbreviated terms and conventions 3.1 Terms and definitions 3.2 Symbols and abbreviated terms |
10 | 3.3 Conventions 4 Principles for designing DTM user interfaces |
11 | 5 Benefits from the FDT user’s point of view |
12 | Figure 2 – Standard User Interface (SUI) |
13 | 6 Functions of a DTM 6.1 General 6.2 Function “Main operation” Figure 3 – Advanced User Interface (AUI) |
14 | 6.3 Functions “Online Parameterize” and “Offline Parameterize” 7 DTM user interface 7.1 Objective 7.2 General behavior |
15 | 7.3 Microsoft Active Accessibility 7.4 Appearance |
16 | Figure 4 – Areas of an SUI |
17 | Figure 5 – Areas of an AUI |
18 | Tableaux Table 1 – Contents of Identification Area |
19 | Table 2 – Contents of Action Area |
20 | Table 3 – Contents of Status Bar Table 4 – Possible connection states |
21 | Table 5 – Possible data source states Table 6 – Possible states of the instance data set Table 7 – Possible device diagnostic states (see [1]) |
22 | 7.5 Parameter handling |
23 | Figure 6 – State diagram: Continuous Check |
24 | Figure 7 – State diagram: One Time Check Figure 8 – Parameter value and associated information |
25 | Table 8 – Possible states of parameters |
26 | 8 Representation of DTM functions Table 9 – Display of inadmissible or wrong data |
27 | Table 10 – Representation of functions |
29 | 9 DTM behavior 9.1 Close of user interface with modified parameter values 9.2 Data set |
30 | 9.3 Online parameterization / data source: device 9.4 Offline parameterization / data source: data set |
31 | 9.5 Error handling 9.6 Communication |
32 | 9.7 Access rights 9.8 Localization 9.9 Documentation Table 11 – Relation between user roles and parameter classes |
33 | 9.10 Installation and un-installation Table 12 – Installation and un-installation |
35 | Bibliography |