ISO 20596-1:2018
$36.40
Water quality — Determination of cyclic volatile methylsiloxanes in water — Part 1: Method using purge and trap with gas chromatography-mass spectrometry (GC-MS)
Published By | Publication Date | Number of Pages |
ISO | 2018-06 | 28 |
This document specifies a method for the quantitative determination of selected cyclic volatile methylsiloxanes (cVMS) in non-filtered water samples by purge and trap extraction with isotope dilution gas chromatography-mass spectrometry (GC-MS).
This method is applicable to the determination of individual cVMS, including:
— octamethylcyclotetrasiloxane (D4);
— decamethylcyclopentasiloxane (D5);
— dodecamethylcyclohexasiloxane (D6);
in surface water, ground water, and wastewater. It can be applied to samples within the concentration range of 0,01 µg/l to 1 µg/l of each of the target compounds. Depending on the matrix, the method may also be applicable to higher concentrations ranging from 1 µg/l to 100 µg/l after suitable dilution of the sample or reduction in sample size.