ASME HST 4 2021
$98.04
ASME HST-4 – 2021 Performance Standard for Overhead Electric Wire Rope Hoists
Published By | Publication Date | Number of Pages |
ASME | 2021 |
This Standard establishes performance requirements for electric wire rope hoists for vertical lifting service involving material handling of freely suspended (unguided) loads using wire rope with one of the following types of suspension: (1) lug (2) hook (3) trolley (4) base or deck mounted (does not include base-mounted winches of the type covered by ASME B30.7) (5) wall or ceiling mounted (does not include base-mounted winches of the type covered by ASME B30.7) This Standard is applicable to hoists manufactured after the date on which this Standard is issued. This Standard is not applicable to (1) damaged or malfunctioning hoists (2) hoists that have been misused or abused (3) hoists that have been altered without authorization of the manufacturer or a qualified person (4) hoists used for the purpose of lifting or lowering people (5) hoists used for the purpose of drawing both the load and the hoist up or down the hoist’s own wire rope (6) hoists used for marine and other applications as required by the U.S. Department of Defense (DOD) unless Nonmandatory Appendix A is invoked The requirements of this Standard shall be applied together with the requirements of ASME B30.16. Please also refer to ASME B30.16 for requirements pertaining to marking, construction, and installation; inspection, testing, and maintenance; and operation.
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | CONTENTS |
6 | FOREWORD |
7 | ASME HST COMMITTEE ROSTER |
8 | CORRESPONDENCE WITH THE HST COMMITTEE |
10 | Chapter 4-0 Scope, Definitions, References, and Appendices SECTION 4-0.1: SCOPE SECTION 4-0.2: DEFINITIONS |
13 | Figures Figure 4-0.2-1 Hoist Mounting Headroom, Lift, and Reach |
14 | SECTION 4-0.3: REFERENCES SECTION 4-0.4: APPENDICES Figure 4-0.2-2 Single and Double Reeving |
16 | Chapter 4-1 Performance SECTION 4-1.1: GENERAL SECTION 4-1.2: HOIST DUTY SERVICE CLASSIFICATION 4-1.2.1 General Considerations 4-1.2.2 Hazardous Locations 4-1.2.3 Duty Classification |
17 | SECTION 4-1.3: APPLICATION ANALYSIS 4-1.3.1 General 4-1.3.2 Fundamental Application Analysis |
18 | Tables Table 4-1.2.3-1 Hoist Duty Service Classification |
19 | 4-1.3.3 Detailed Application Analysis SECTION 4-1.4: SPECIFICATION OF LIFT, HEADROOM, AND REACH 4-1.4.1 Lift 4-1.4.2 Headroom 4-1.4.3 Reach SECTION 4-1.5: SPEEDS: HOIST AND TROLLEY SECTION 4-1.6: TYPES OF TROLLEYS 4-1.6.1 Plain Type 4-1.6.2 Hand-Chain Operated |
20 | 4-1.6.3 Motor Operated 4-1.6.4 Trolley Wheels Table 4-1.5-1 Typical Hoist and Motorized Trolley Speeds |
21 | Chapter 4-2 Mechanical SECTION 4-2.1: REEVING 4-2.1.1 Single Reeving 4-2.1.2 Double Reeving SECTION 4-2.2: BEARINGS SECTION 4-2.3: OVERLOAD LIMITING DEVICE |
22 | Chapter 4-3 Electrical SECTION 4-3.1: GENERAL 4-3.1.1 Hazardous Locations 4-3.1.2 Fungus Protection SECTION 4-3.2: MOTORS Table 4-3.2-1 Typical Rated Motor Voltages |
23 | SECTION 4-3.3: CONTROLLERS 4-3.3.1 Types of Control 4-3.3.2 Contactors 4-3.3.3 Pendant Control 4-3.3.4 Pull-Cord Control SECTION 4-3.4: CONTROL ENCLOSURES |
24 | SECTION 4-3.5: RESISTORS SECTION 4-3.6: CURRENT CONDUCTOR SYSTEMS |
25 | Chapter 4-4 Typical Electric Wire Rope Hoist and Trolley Inquiry Data Form SECTION 4-4.1: INQUIRY DATA FORM |
26 | Form FORM 4-4.1-1 Typical Electric Wire Rope Hoist and Trolley Inquiry Data Form |
27 | NONMANDATORY APPENDIX A PERFORMANCE REQUIREMENTS FOR ELECTRIC WIRE ROPE HOISTS USED IN MARINE AND OTHER APPLICATIONS AS REQUIRED BY THE U.S. DEPARTMENT OF DEFENSE (DOD) A-1 GENERAL |
28 | A-2 PERFORMANCE REQUIREMENTS |
29 | Table A-3.2-1 Hook Throat Openings A-3 MECHANICAL REQUIREMENTS |
31 | A-4 ELECTRICAL A-5 TESTING, MARKING, AND DATA |
32 | Table A-4.2.5-1 Electromagnetic Environment |
33 | A-6 TYPICAL HOIST INQUIRY DATA |
34 | NONMANDATORY APPENDIX B EXAMPLES OF DETAILED APPLICATION ANALYSIS B-1 TYPICAL EXAMPLES OF HOIST CLASS SELECTION |
35 | Table B-2-1 Example of Detailed Analysis Worksheet B-2 DETAILED ANALYSIS WORKSHEET |
37 | NONMANDATORY APPENDIX C MECHANICAL SPARK RESISTANCE GUIDANCE FOR APPLICATIONS IN HAZARDOUS (POTENTIALLY EXPLOSIVE) LOCATIONS C-1 GENERAL |
38 | C-2 USE OF REFERENCED DOCUMENTS C-3 MECHANICAL SPARK RESISTANCE |
41 | C-4 EXCESSIVE SURFACE TEMPERATURE C-5 HOIST INSPECTION CONSIDERATIONS |