{"id":154741,"date":"2024-10-19T09:12:37","date_gmt":"2024-10-19T09:12:37","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-iec-62582-2-amd1-2016\/"},"modified":"2024-10-25T01:28:04","modified_gmt":"2024-10-25T01:28:04","slug":"ieee-iec-62582-2-amd1-2016","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-iec-62582-2-amd1-2016\/","title":{"rendered":"IEEE IEC 62582 2 amd1 2016"},"content":{"rendered":"
Amendment Standard – Active. The scope is the correction of Figure 1, Figure 2, Figure A. 1 and Figure B.1 of IEC\/IEEE 62582-2:2011.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEC\/IEEE 62582-2-amd1:2016 Front cover <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Title page <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | English FOREWORD <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | 6 Measurement procedur 6.4 Instrumentation Figure 1 \u2013 Geometry and dimensions of the profileof the probe tip (truncated cone) used in the indenter 6.9 Determination of the value of the indenter modulus Figure 2 \u2013 Calculation of indenter modulus <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Annex A (informative) A.1 Example of influence of variability in equipment dimensions and construction Figure A.1 \u2013 Example of local variation of indenter modulus due to variation inequipment dimensions and construction Annex B (informative) Figure B.1 \u2013 Example of measured force versus time <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Fran\u00e7ais AVANT-PROPOS <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 6 Proc\u00e9dure de mesure 6.4 Instrumentation Figure 1 \u2013 G\u00e9om\u00e9trie et dimensions correspondant au profil de l\u2019extr\u00e9mit\u00e9de la sonde (c\u00f4ne tronqu\u00e9) utilis\u00e9e pour le poin\u00e7onn 6.9 D\u00e9termination de la valeur du module indenter Figure 2 \u2013 Calcul du module indenter <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Annexe A (informative) A.1 Exemple de l\u2019influence des diff\u00e9rents types de construction et diff\u00e9rentesdimensions d\u2019\u00e9quipement Figure A.1 \u2013 Exemple de variation locale de la valeur du module indenter due \u00e0 lavariation de dimension et de construction de l\u2019\u00e9quipement Annexe B (informative) Figure B.1 \u2013 Exemple de la force mesur\u00e9e en fonction du temps <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEC\/IEEE International Standard for Nuclear power plants — Instrumentation and control important to safety — Electrical equipment condition monitoring methods — Part 2: Indenter modulus – Amendment 1<\/b><\/p>\n |