{"id":219406,"date":"2024-10-19T14:14:06","date_gmt":"2024-10-19T14:14:06","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-12350-82019-tc\/"},"modified":"2024-10-25T07:34:22","modified_gmt":"2024-10-25T07:34:22","slug":"bs-en-12350-82019-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-12350-82019-tc\/","title":{"rendered":"BS EN 12350-8:2019 – TC"},"content":{"rendered":"
This document specifies the procedure for determining the slump-flow and t500 time for self-compacting concrete. The test is suitable for specimens having a declared value of D of the coarsest fraction of aggregates actually used in the concrete (Dmax) not greater than 40 mm.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
19<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions 4 Principle 5 Apparatus <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 6 Test sample 7 Procedure <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 8 Test result 9 Test report <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 10 Repeatability and reproducibility <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Tracked Changes. Testing fresh concrete – Self-compacting concrete. Slump-flow test<\/b><\/p>\n |