{"id":242225,"date":"2024-10-19T15:52:29","date_gmt":"2024-10-19T15:52:29","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-506182014\/"},"modified":"2024-10-25T10:44:13","modified_gmt":"2024-10-25T10:44:13","slug":"bs-en-506182014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-506182014\/","title":{"rendered":"BS EN 50618:2014"},"content":{"rendered":"

This European Standard applies to low smoke halogen-free, flexible, single-core power cables with cross-linked insulation and sheath. In particular for use at the direct current (d.c.) side of photovoltaic systems, with a nominal d.c. voltage of 1,5 kV between conductors and between conductor and earth.<\/p>\n

The cables are suitable to be used with Class II equipment.<\/p>\n

The cables are designed to operate at a normal maximum conductor temperature of 90 \u00b0C, but for a maximum of 20 000 hours a max. conductor temperature of 120 \u00b0C at a max. ambient temperature of 90 \u00b0C is permitted.<\/p>\n

\n
\n NOTE\n <\/div>\n

The expected period of use under normal usage conditions as specified in this standard is at least 25 years.<\/p>\n<\/div>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
6<\/td>\nForeword <\/td>\n<\/tr>\n
7<\/td>\nIntroduction <\/td>\n<\/tr>\n
8<\/td>\n1 Scope
2 Normative references <\/td>\n<\/tr>\n
9<\/td>\n3 Terms and definitions <\/td>\n<\/tr>\n
10<\/td>\n4 Rated voltage
5 Requirements for the construction of cables
5.1 Conductors
5.1.1 Material
5.1.2 Construction
5.1.3 Separator between conductor and insulation
5.1.4 Check of construction
5.1.5 Electrical resistance
5.2 Insulation
5.2.1 Material
5.2.2 Application to the conductor <\/td>\n<\/tr>\n
11<\/td>\n5.2.3 Thickness
5.3 Sheath
5.3.1 Material
5.3.2 Application
5.3.3 Thickness <\/td>\n<\/tr>\n
12<\/td>\n5.3.4 Colour
6 Marking
6.1 General
6.2 Indication of origin
6.3 Code designation
6.4 Nominal cross-sectional area of conductor
6.5 Continuity of marking
Figure 1 \u2013 Example of the marking as used on the outer sheath of the cable
6.6 Use of the name CENELEC <\/td>\n<\/tr>\n
13<\/td>\n6.7 Additional requirements
6.7.1 Durability
6.7.2 Legibility
7 Requirements for completed cables
7.1 General
7.2 Electrical tests
7.2.1 Voltage test on completed cable
7.2.2 Check for absence of faults on the insulation or on the complete cable
7.2.3 Measurement of insulation resistance
7.2.4 Long term resistance of insulation to d.c <\/td>\n<\/tr>\n
14<\/td>\n7.2.5 Surface resistance of sheath
7.3 Non electrical tests
7.3.1 Sheath colour
7.3.2 Sheath marking
7.3.3 Overall diameters and ovality
7.3.4 Compatibility
7.3.5 Cold impact
7.3.6 Cold bending
7.3.7 Cold elongation
7.3.8 Ozone resistance <\/td>\n<\/tr>\n
15<\/td>\n7.3.9 Weathering\/UV resistance
7.3.10 Dynamic penetration
7.3.11 Damp heat test
7.3.12 Shrinkage
7.3.13 Vertical flame propagation
7.3.14 Smoke emission
7.3.15 Assessment of halogens <\/td>\n<\/tr>\n
16<\/td>\nTable 1 \u2014 Dimensional and insulation resistance values <\/td>\n<\/tr>\n
17<\/td>\nTable 2 \u2014 Tests for cables to EN 50618 <\/td>\n<\/tr>\n
22<\/td>\nAnnex A (normative) Guide to use \u2013 Use of cables for PV systems <\/td>\n<\/tr>\n
23<\/td>\nTable A.1 \u2014 Intended use of cables for PV systems (environmental conditions) <\/td>\n<\/tr>\n
24<\/td>\nTable A.2 \u2014 Recommended use of cables for PV systems
Table A.3 \u2014 Current carrying capacity of PV cables <\/td>\n<\/tr>\n
25<\/td>\nTable A.4 \u2014 Current rating conversion factors for different ambient temperatures <\/td>\n<\/tr>\n
26<\/td>\nAnnex B (normative) Requirements for insulation and sheathing materials
Table B.1 \u2014 Requirements for insulation and sheathing materials <\/td>\n<\/tr>\n
28<\/td>\nAnnex C (normative) Cold impact test
Table C.1 \u2014 Parameters for cold impact test <\/td>\n<\/tr>\n
29<\/td>\nAnnex D (normative) Dynamic penetration test
Figure D.1 \u2014 Arrangement for dynamic penetration test <\/td>\n<\/tr>\n
30<\/td>\nAnnex E (normative) Weathering\/UV resistance test <\/td>\n<\/tr>\n
31<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Electric cables for photovoltaic systems (BT(DE\/NOT)258)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2015<\/td>\n34<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":242232,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[493,2641],"product_tag":[],"class_list":{"0":"post-242225","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-060-20","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/242225","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/242232"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=242225"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=242225"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=242225"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}