AAMI TIR44:2012 – Technical Information Report Non-invasive blood pressure motion artifact – Testing and evaluation of NIBP device performance in the presence of motion artifact

Published By Publication Date Number of Pages
AAMI 2012 39
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This report is intended to provide information on the sources and effects of artifact noise in noninvasive blood pressure measurement. The report also includes an overview of potential evaluation methods for the qualification and classification of device performance when varying levels of artifact noise are present during an NIBP cycle.

PDF Catalog

PDF Pages PDF Title
1 AAMI TIR44:2012, Non-invasive blood pressure motion artifact – Testing and evaluation of NIBP device performance in the presence of motion artifact
3 Title page
4 AAMI Technical Information Report
Copyright information
5 Contents
7 Glossary of equivalent standards
8 Committee representation
9 Acknowledgment
10 Foreword
11 Introduction
13 1 Scope
1.1 General
1.2 Exclusions
2 Normative references
3 Terms and definitions
15 4 Sources of Artifact Noise
4.1 Patient induced
16 4.2 Patient ambulation
4.3 Transport
4.4 Physiologic artifact
17 4.5 Summary
18 5 Effect of Artifact on NIBP readings
5.1 Summary of literature
5.1.1 Simulation and Testing
5.1.2 Transport
5.1.3 Exercise Testing
19 5.1.4 Ambulatory Blood Pressure Monitoring (ABPM)
5.2 Magnitude of common artifact
5.3 Spectral content of common artifact
5.4 Examples of common artifact
5.4.1 Arm reposition
21 5.4.2 Tremor
23 5.4.3 Transport (Helicopter)
25 5.4.4 Transport (Ground Ambulance)
29 6 Relevance of existing standards and protocols
6.1 ANSI/AAMI SP10:2008, superseded by ANSI/AAMI/ISO 81060-2:2009
6.2 CEN/EN 1060-4
6.3 ANSI/AAMI ES60601-1:2005, A1:2012
6.4 ANSI/AAMI/IEC 80601-2-30:2009
6.5 ANSI/AAMI/ISO 81060-2:2009
6.6 BHS protocol for the evaluation of blood pressure measurement devices
30 6.7 Summary of existing standards
7 Working group scope and goals
7.1 WG Scope
7.2 General Goals
31 8 Motion artifact performance evaluation methods
8.1 Challenges
8.1.1 Reference Readings
8.1.2 Blood pressure variation
8.1.3 Test Repeatability
8.1.4 Test subject mobility
8.1.5 Proprietary Systems
8.2 General concepts for motion artifact evaluation
8.2.1 SP10 baseline plus noise approach
32 8.2.2 Case-specific test approach
8.3 Implementation into NIBP standards
8.3.1 Required minimum level of artifact tolerance for intended use
8.3.2 Voluntary “motion tolerant” labeling
8.3.3 Rankings or levels of motion tolerance
8.4 Test methods
8.4.1 Simulator vs Clinical Protocol
33 8.5 Intended use focused recommendations (preliminary)
8.5.1 Stress testing
8.5.1.1 General Approach
8.5.1.2 Types of artifact noise in scope
8.5.1.3 Testing Protocol
34 8.5.1.4 Reporting of Results
8.5.1.5 Open Issues
8.5.2 Transport
8.5.2.1 General Approach
8.5.2.2 Types of artifact noise in scope
35 8.5.2.3 Testing Protocol
8.5.2.4 Reporting of Results
8.5.2.5 Open Issues
8.5.3 Patient Ambulation (ABPM)
8.5.3.1 General Approach
8.5.3.2 Types of artifact noise in scope
36 8.5.3.3 Testing Protocol
8.5.3.4 Reporting of Results
8.5.3.5 Open Issues
8.6 Whole body vibration
9 Working Group recommendations and next steps
37 10 References