ASME BPVC – VII -2010 BPVC Section VII, Recommended Guidelines for the Care of Power Boilers

Published By Publication Date Number of Pages
ASME 2010 158
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

None

PDF Catalog

PDF Pages PDF Title
5 CONTENTS
9 LIST OF SECTIONS
11 FOREWORD
13 STATEMENT OF POLICY
14 PERSONNEL
26 INTRODUCTION
27 SUMMARY OF CHANGES
29 SUBSECTION C1 FUNDAMENTALS
C1.100 STEAM GENERATION
C1.200 BOILER TYPES
30 C1.300 PACKAGE BOILERS
C1.400 FIELD- ASSEMBLED BOILERS
C1.500 COMBUSTION
FIGURES
FIG. C1.2-1 SIMPLE STEAM DRUM
FIG. C1.2-2 STEAM DRUM WITH TUBES
31 FIG. C1.2-3a STEAM DRUM INTERNALS — BAFFLE TYPE
FIG. C1.2-3b STEAM DRUM INTERNALS DOUBLE-ROW ARRANGEMENT,CYCLONE SEPARATOR TYPE
32 C1.600 BOILER EFFICIENCY
33 SUBSECTION C2 BOILER OPERATION
C2.100 GENERAL GUIDELINES
34 C2.200 PREPARING FOR OPERATION
37 C2.300 STARTING UP
39 C2.400 ON- LINE OPERATION
43 C2.500 OUT- OF- SERVICE OPERATION
46 SUBSECTION C3 BOILER AUXILIARIES
C3.100 PREPARATION OF AUXILIARIES FOR SERVICE
C3.200 FUEL- BURNING EQUIPMENT
FIGURES
FIG. C3.2-1 TYPICAL PILOT AND GAS PIPING ARRANGEMENT
47 FIG. C3.2-2 TYPICAL FUEL OIL TRAIN
49 FIG. C3.2-3 TYPICAL UNDERFEED STOKER
FIG. C3.2-4 FEEDER–DISTRIBUTOR FOR FIRING OF COAL ON A SPREADER STOKER
52 FIG. C3.2-5 SPREADER STOKER, CONTINUOUS ASH DISCHARGE GRATE
53 FIG. C3.2-6 TYPICAL BOWL MILL
56 FIG. C3.2-7 TYPICAL IMPACT MILL
57 FIG. C3.2-8 ARRANGEMENT OF BALL-TUBE MILL
FIG. C3.2-9 BURNER FOR HORIZONTAL FIRING OF COAL
59 C3.300 AIR HEATERS
60 FIG. C3.3-1 TYPICAL TUBULAR AIR HEATER
61 FIG. C3.3-2 TYPICAL REGENERATIVE AIR HEATER
62 C3.400 ECONOMIZERS
FIG. C3.3-3 DETAILS OF REGENERATIVE AIR PREHEATER, BISECTOR TYPE
63 FIG. C3.4-1 TYPICAL ECONOMIZER
64 C3.500 BOILER FEED PUMPS
C3.600 AUXILIARY DRIVES
65 FIG. C3.5-1 TYPICAL CENTRIFUGAL BOILER FEED PUMP, WATER CONNECTIONS
66 FIG. C3.6-1 TYPICAL MOTOR DRIVE
FIG. C3.6-2 TYPICAL SINGLE STAGE TURBINE DRIVE
67 FIG. C3.6-3 TYPICAL TURBINE DRIVE ARRANGEMENT
68 C3.700 DRAFT FANS
C3.800 DAMPERS
69 FIG. C3.7-1 AIRFOIL BLADE CENTRIFUGAL FAN WITH INLET VANE CONTROL
FIG. C3.8-1 TYPICAL OUTLET FAN DAMPERS (MULTILOUVER)
71 SUBSECTION C4 APPURTENANCES
C4.100 SAFETY VALVES
72 FIGURES
FIG. C4.1-1 SAFETY VALVE NAMEPLATE
73 FIG. C4.1-2 TYPICAL SAFETY VALVE
74 FIG. C4.1-3 RECOMMENDED SAFETY VALVE INSTALLATION
76 FIG. C4.1-4 APPLICATION OF TEST GAG
77 FIG. C4.1-5 HYDRAULIC LIFT ASSIST DEVICE
78 C4.200 SAFETY RELIEF VALVES OR RELIEF VALVES
79 FIG. C4.2-1 TEST APPARATUS FOR SEAT TIGHTNESS
TABLE
TABLE C4.2-1 LEAKAGE RATES FOR SAFETY RELIEF VALVES FOR SET PROCEDURES
80 C4.300 PRESSURE GAGES
81 C4.400 FUSIBLE PLUGS
C4.500 FEEDWATER REGULATOR VALVE
C4.600 BLOWDOWN
C4.700 SOOT BLOWERS
83 SUBSECTION C5 INSTRUMENTATION, CONTROLS, AND INTERLOCKS
C5.100 GENERAL
C5.200 INDICATORS AND RECORDERS
84 C5.300 CONTROLS AND INTERLOCKS
86 SUBSECTION C6 INSPECTION
C6.100 SCOPE
C6.200 INSPECTION FREQUENCY
FIGURES
FIG. C6.1-1 TYPICAL BOILER WATER LEVEL GAGE INSTALLATION
87 C6.300 PREPARATION FOR INSPECTION
C6.400 INSPECTION OF INTERNAL SURFACES AND PARTS
88 FIG. C6.3-1 TYPICAL VALVE LINEUP PRIOR TO INSPECTION
90 FIG. C6.4-1 TYPICAL STAYS
91 FIG. C6.4-2 TYPICAL FORMS OF FUSIBLE PLUGS
92 C6.500 INSPECTION OF EXTERNAL SURFACES AND PARTS
93 C6.600 CARE AND MAINTENANCE
94 C6.700 REPAIRS
C6.800 HYDROSTATIC TEST
C6.900 BOILERS — GENERAL
95 C6.1000 AUTHORIZED INSPECTOR
96 SUBSECTION C7 REPAIRS, ALTERATIONS, AND MAINTENANCE
C7.100 REPAIRS AND ALTERATIONS
C7.200 MAINTENANCE
97 C7.300 BOILER MAINTENANCE PROGRAMS
98 C7.400 STEAM BOILERS
104 SUBSECTION C8 CONTROL OF INTERNAL CHEMICAL CONDITIONS
C8.100 GENERAL
C8.200 INTERNAL CLEANING OF BOILERS
105 C8.300 LAYING UP OF BOILERS
106 C8.400 DEPOSITS
107 FIGURE
FIG. C8.4-1 SCALE CAUSING OVERHEATING AND TUBE FAILURE
FIG. C8.4-2 DEPOSIT EFFECT ON BOILER TUBE VERSUS TUBE TEMPERATURE
108 C8.500 INTERNAL CORROSION
109 FIG. C8.5-1 OXYGEN CORROSION IN AN ECONOMIZER TUBE
FIG. C8.5-2 CAUSTIC GOUGE-TYPE ATTACK ON BOILER TUBE
110 FIG. C8.5-3 CHELATE ATTACK CAUSED BY EXCESSIVE FEED OF CHEMICAL
111 FIG. C8.5-4 CO2 CARBONIC ACID ATTACK ON CONDENSATE PIPE
FIG. C8.5-5 OXYGEN ATTACK ON CONDENSATE PIPE
112 C8.600 CORROSION CRACKING OF BOILER STEEL
113 C8.700 STEAM CONTAMINATION
114 FIG. C8.6-1 H+ DAMAGE ON BOILER TUBE
115 C8.800 SAMPLING, TESTING, CONTROLLING, AND REPORTING OF ANALYSES OF WATER
C8.900 FIRE- SIDE CONDITIONS
TABLE
TABLE C8.8-1METHODS FOR SAMPLING OF WATER AND STEAM
116 TABLE C8.8-2 METHODS OF ANALYSIS FOR THE CONTROL OF WATER FOR BOILERS
117 TABLE C8.8-3 USEFUL TESTS FOR THE CONTROL OF WATER FOR BOILERS
119 SUBSECTION C9 PREVENTING BOILER FAILURES
C9.100 GENERAL
C9.200 OVERPRESSURE
121 C9.300 WEAKENING OF STRUCTURE
124 C9.400 OPERATION OF COMBUSTION EQUIPMENT
125 C9.500 FURNACE EXPLOSIONS
C9.600 FURNACE IMPLOSIONS
127 MANDATORY APPENDICES
I SUBMITTAL OF TECHNICAL INQUIRIES TO THE BOILER AND PRESSURE VESSEL COMMITTEE
129 II STANDARD UNITS FOR USE IN EQUATIONS
130 NONMANDATORY APPENDICES
A PROCEDURES FOR CARE AND MAINTENANCE OF PACKAGE BOILERS
131 B WATERTUBE BOILERS — MAINTENANCE CHECKS
138 C WATERTUBE BOILERS — OPERATING CHECKS RELATING TO MAINTENANCE
140 D FIRETUBE BOILERS — MAINTENANCE CHECKS
141 E FIRETUBE BOILERS — OPERATING CHECKS RELATING TO MAINTENANCE
142 F GUIDANCE FOR THE USE OF U. S. CUSTOMARY AND SI UNITS IN THE ASME BOILER AND PRESSURE VESSEL CODE
145 GLOSSARY