ASTM-C1442:2003 Edition
$40.63
C1442-03 Standard Practice for Conducting Tests on Sealants Using Artificial Weathering Apparatus
Published By | Publication Date | Number of Pages |
ASTM | 2003 | 5 |
1.1 This practice covers three types of laboratory weathering exposure procedures for evaluating the effect of actinic radiation, heat, and moisture on sealants.
1.2 The exposure sources used in the three types of artificial weathering devices are the filtered xenon arc, fluorescent ultraviolet lamps, and open flame carbon arc based on Practices G 155, G 154, and G 152, respectively.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are provided for information only.
1.4 The ISO standard related to this Practice is ISO 11431. Significant differences exist between the procedures. The ISO specimens are exposed through glass and are elongated prior to examination for loss of adhesion or cohesion, or both, following exposure.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology Summary of Practice Significance and Use |
2 | Test Specimen Apparatus |
3 | Conditioning Procedure Report Precision and Bias Keywords |
4 | A1. Xenon Arc Radiant Exposure Versus Time A1.1 Xenon Arc Irradiance Setting A1.2 Times for Equivalent Radiant Exposures at Different Xenon Arc Irradiance Levels X1. IRRADIANCE SPECIFICATION FOR XENON ARC EXPOSURE X1.1 Justification for the Xenon Arc Recommended Irradiance Setting of 0.51 W/(m2 · nm) at 340 nm X2. EFFECT OF EXPOSURE AT DIFFERENT IRRADIANCE LEVELS X2.1 |
5 | References |