C449-07 Standard Specification for Mineral Fiber Hydraulic-Setting Thermal Insulating and Finishing Cement (Redline)

Published By Publication Date Number of Pages
ASTM 2007 4
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

Abstract

This specification covers mineral fiber (rock or slag) insulating and finishing cement shipped in dry-mix form, including hydraulic-setting binder, which, when mixed with water and applied in accordance with the manufacturer’s directions, affords a smooth surface as a final finish for heated surfaces for specific applications. The actual temperature limit shall be agreed upon between the purchaser and the manufacturer. Specimens shall be sampled, prepared, tested, and conform accordingly to the following properties: dry covering capacity, volume change upon drying, compressive strength, linear shrinkage, apparent thermal conductivity, maximum use temperature, and non-combustibility.

This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

1. Scope

1.1This specification covers mineral fiber (rock or slag) insulating and finishing cement shipped in dry-mix form, including hydraulic-setting binder, which, when mixed with water and applied in accordance with the manufacturer’s directions, affords a smooth surface as a final finish for heated surfaces up to 1200Ā°F (649 Ā°C) for specific applications. The actual temperature limit shall be agreed upon between the purchaser and the manufacturer.

Note 1ā€” Precautionary measures should be taken with this material as with other hydraulic-setting mixtures. This material should be used within the time period recommended by the manufacturer.

1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.3 The following safety hazards caveat pertains only to the test method (Section 10) described in this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.4 When the installation or use of thermal insulation materials, accessories, and systems pose safety or health problems, the manufacturer shall provide the user with appropriate current information regarding any known problems associated with the recommended use of the company’s products and shall also recommend protective measures to be employed in their safe utilization. The user shall establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

ASTM Standards

C163 Practice for Mixing Thermal Insulating Cement Samples C166 Test Method for Covering Capacity and Volume Change Upon Drying of Thermal Insulating Cement C168 Terminology Relating to Thermal Insulation C177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus C356 Test Method for Linear Shrinkage of Preformed High-Temperature Thermal Insulation Subjected to Soaking Heat C390 Practice for Sampling and Acceptance of Thermal Insulation Lots C411 Test Method for Hot-Surface Performance of High-Temperature Thermal Insulation C518 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus C795 Specification for Thermal Insulation for Use in Contact with Austenitic Stainless Steel C1045 Practice for Calculating Thermal Transmission Properties Under Steady-State Conditions C1058 Practice for Selecting Temperatures for Evaluating and Reporting Thermal Properties of Thermal Insulation C1114 Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus E136 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750C

Keywords

cement; finishing; hydraulic-setting; insulating; mineral fiber; thermal; thermal conductivity;

ICS Code

ICS Number Code 91.100.10 (Cement. Gypsum. Lime. Mortar)