C799-99(2005) Standard Test Methods for Chemical, Mass Spectrometric, Spectrochemical, Nuclear, and Radiochemical Analysis of Nuclear-Grade Uranyl Nitrate Solutions

Published By Publication Date Number of Pages
ASTM 2005 14
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

ASTM C799-99-Reapproved2005

Historical Standard: Standard Test Methods for Chemical, Mass Spectrometric, Spectrochemical, Nuclear, and Radiochemical Analysis of Nuclear-Grade Uranyl Nitrate Solutions

ASTM C799

Scope

1.1 These test methods cover procedures for the chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of nuclear-grade uranyl nitrate solution to determine compliance with specifications.

1.2 The analytical procedures appear in the following order:

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 5.

7.1 Uranium can be determined using iron (II) reduction and dichromate titration. Test Method C1267 can be used.

7.2 Uranium can also be determined using cerium (IV) oxidation titrimetry. ISO 7097 Test Method can be used.

7.3 Uranium can also be determined by X-Ray Fluorescence using Test Method C1254.

7.4 Previous sections have been deleted.

8.1 This test method covers the determination of uranium in nuclear-grade uranyl nitrate solution. Appropriate size sample aliquots are chosen to obtain 5 to 10 g of U3O8.

15.1 This test method covers the determination of the specific gravity of a solution of uranyl nitrate to Ā±0.0004.

21.1 This test method covers the determination of the free acid content of uranyl nitrate solutions that may contain a ratio of up to 5 moles of acid to 1 mole of uranium.

28.1 The determination of thorium by the arsenazo (III) (photometric) method has been discontinued, (see C799-93).

28.2 As an alternative, thorium can be determined using Inductively Coupled Plasma Mass Spectrometry (ICP-MS). See Test Method C1287.

28.3 Previous sections have been deleted.

29.1 The determination of chromium by the diphenyl carbazide method has been discontinued, (see C799-93).

29.2 As an alternative, chromium can be determined using inductively coupled plasma atomic emission spectrometry (ICP-AES). Test Method C761 can be used providing a transformation to U3O8 so described hereafter in sections 117ā€“120 A direct conversion to the amonium fluoride plus nitric acid solution can also be used, (see C761).

29.3 As an alternative, chromium can be determined using atomic absorption spectroscopy. Test Method C761 can be used.

29.4 As an alternative, chromium can be determined using ICP-MS. Test Method C1287 can be used.

29.5 Previous sections have been deleted.

30.1 The determination of molybdenum by the thiocyanate (photometric) method has been discontinued, (See C799-93).

30.2 As an alternative, molybdenum can be determined using ICP-MS. Test Method C1287 can be used.

30.3 As an alternative, molybdenum can be determined using ICP-AES. Test Method C761, sections 251 to 271 can be used providing a tranformation to U3O8 as described hereafter in sections 71-74. A direct conversion to the amonium fluoride plus nitric acid solution can also be used, (see C761, section 251).

30.4 Previous sections have been deleted.

31.1 This test method covers the separation of the halogens by means of a steam distillation.

36.1 This test method covers the determination of as low as 2 Ī¼g F/g U in distillate containing all the halogens.

43.1 The determination of chloride, bromide and iodide by microtitrimetric method has been discontinued, (see C799-93).

43.2 Previous sections have been deleted.

44.1 Determination of bromide by the fluorescein (photometric) method has been discontinued, (see C799-93).

44.2 As an alternative, bromide and chloride can be determined by X-Ray Fluorescence. Halogens are precipitated by silver nitrate and filtrated. The precipitate is washed and counted by X-Ray Fluorescence.

44.3 Previous sections have been deleted.

45.1 Sulfur can be determined using X-Ray Fluorescence. See Test Method C1296.

46.1 This test method covers the determination of the sulfur concentration, which exists as sulfate in uranyl nitrate solutions, in the range from 100 to 1000 Ī¼g S/g of uranium.

54.1 This test method covers determination of phosphorus in nuclear-grade uranyl nitrate solutions. Appropriate dilution may be made to facilitate obtaining samples containing 0 to 60 Ī¼g P.

62.1 This test method covers the determination of up to 20 Ī¼g Si (2 to 200 Ī¼g Si/g U) in uranyl nitrate solutions.

70.1 Determination of carbon by the persulfate oxidation titrimetry method has been discontinued, (see C799-93).

70.2 Previous sections have been deleted.

71.1 This test method is specifically designed for the conversion of uranyl nitrate to U3O8.

75.1 This test method covers the determination of 0.05 to 33 Ī¼g B/g of uranium.

82.1 The determination of impurities by spark source mass spectrography method has been discontinued, (see C799-93).

82.2 Previous section have been deleted.

83.1 The determination of isotopic composition using a single collector thermal ionisation mass spectrometer has been discontinued, (see C799-93 and C696).

83.2 As an alternative, the isotopic composition can be measured using a multi- collector thermal ionisation spectrometer. Test Method C1413 can be used.

83.3 As an alternative, the isotopic composition can be measured using isotope dilution mass spectormetry. Test Method C1380 can be used.

83.4 Previous section have been deleted.

84.1 This test method covers the determination of uranium-232 in nuclear-grade uranyl nitrate solutions, in concentrations as low as 0.05 ng 232U/ 235U.

91.1 This test method covers the determination of the sum of all alpha-emitting nuclides in uranyl nitrate solutions.

98.1 This test method covers the measurement of the beta emitters fission product activity of nuclear-grade uranyl nitrate solutions.

105.1 The determination of entrained organic matter by infrared spectrophotometry method has been discontinued, (see C799-93).

106.1 The determination of gamma emiters fission products can be done with Test Method C1295.

107.1 The determination of arsenic can be done with atomic absorption. Test Method C1219 can be used.

107.2 As an alternative, arsenic can be determined using ICP-MS. Test Method C1287 can be used.

108.1 The determination of impurities for the Equivalent Boron Content can be done with ICP-MS. Test Method C1287 can be used. The EBC table described in C1233 can be used.

109.1 The determination of Technetium 99 can be done using ICP-MS. Test Method C1287 can be used.

109.2 As an alternative, Technetium can be determined after solvent extraction by beta counting. Test Method C761 can be used.

110.1 Plutonium can be determined by alpha counting after ion exchange. Test Method C761 can be used.

110.2 As an alternative, plutonium can be determined by alpha counting after solvent extraction. Test Method C761 can be used.

110.3 Neptunium can be determined by alpha counting after solvent extraction. Test Method C761 can be used.

110.4 Previous sections have been deleted.

Keywords

impurity content; isotopic composition; stoichiometry; uranium content; uranyl nitrate

ICS Code

ICS Number Code 27.120.30 (Fissile materials and nuclear fuel technology)

DOI: 10.1520/C0799-99R05

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
2 Significance and Use
Reagents
Safety Precautions
Sampling
Scope
Scope
Summary of Test Method
Interferences
Apparatus
Procedure
3 Calculation
Precision
Scope
Summary of Test Method
Apparatus
Procedure
Calculation
Precision
Scope
Summary of Test Method
Apparatus
Reagents
Procedure
Calculation
4 Precision
Scope
Scope
Scope
Scope
Summary of Test Method
Apparatus
Reagents
Procedure
FIG. 1
5 Scope
Summary of Test Method
Apparatus
Reagents
Procedure
Calculation
Precision
Scope
Scope
Scope
Scope
Summary of Test Method
Interferences
6 Apparatus
Reagents
Procedure
Calculation
Precision
Scope
Summary of Test Method
Interferences
Apparatus
Reagents
Procedure
7 Calculation
Precision
Scope
Summary of Test Method
Interferences
Apparatus
Reagents
Procedure
Calculation
Precision
Scope
8 Scope
Summary of Test Method
Apparatus
Procedure
Scope
Summary of Test Method
Apparatus
Reagents
Procedure
9 Calculation
Precision
Scope
Scope
Scope
Summary of Test Method
Apparatus
Reagents and Materials
Procedure
10 Calculation
FIG. 2
11 Precision
Scope
Summary of Test Method
Apparatus
Reagents
Procedure
Calculation
Precision
Scope
Summary of Test Method
Apparatus
12 Reagents
Procedure
Calculation
13 Precision
Scope
Scope
Scope
Scope
Scope
Scope
Keywords
REFERENCES
ASTM-C799 2005
$44.96