1.1 This specification covers the minimum requirements for, and methods of, application of gypsum veneer base for gypsum veneer plasters.

1.2 Gypsum veneer base shall not be used as a base for direct adhesive application of ceramic, metal, or plastic tile in areas exposed to abnormal moisture or humidity or temperature.

1.3 Details of construction for a specific assembly to achieve the required fire resistance shall be obtained from reports of fire-resistance tests, engineering evaluations, or listings from recognized fire testing laboratories.

1.4 Where a specific degree of sound control is required for veneer plaster assemblies and constructions, details of construction shall be in accordance with official reports of tests conducted in recognized sound testing laboratories in accordance with the applicable sound tests, Test Method C423 , Test Method E90 , or Test Method E492 .

1.5 Where this specification is more stringent (size or thickness of framing; spacing of fasteners) than the fire-rated construction, this specification shall govern; otherwise, the construction described in the fire test report shall govern.

1.6 Unheated spaces above gypsum veneer base ceilings shall be properly ventilated (see Appendix X3).

1.7 The values stated in inch-pound units are to be regarded as the standard. The SI (metric) values given in parentheses are approximate and are provided for information purposes only.

1.8 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
2 Terminology
Materials
Delivery of Materials
Shipping, Handling and Storage
Environmental Conditions
Application of Gypsum Base
3 Application of Single-Ply Gypsum Base
TABLE 1
4 Adhesive-Mechanical Fastener Application
Application over Existing Surfaces
Foil-Backed Gypsum Base
FIG. 1
5 Application of Two-Ply Gypsum Base to Framing Members
FIG. 2
FIG. 3
FIG. 4
6 Solid Gypsum Base Partitions
Adhesive Application of Gypsum Base to Interior Masonry or Concrete Walls
FIG. 5
FIG. 6
7 Gypsum Base Application over Steel Framing and Furring
Application to Arches
TABLE 2
TABLE 3
TABLE 4
TABLE 5
8 Keywords
X1. GENERAL INFORMATION
X1.1
X2. WOOD FRAMING REQUIREMENTS
X2.1
X3. VENTILATING ABOVE GYPSUM BASE CEILINGS
X3.1
9 X4. CABLE ELECTRIC RADIANT HEATING SYSTEMS FOR CEILINGS
X4.1
ASTM-C844 2010
$40.63