ASTM-D3032 2004
$63.38
D3032-04 Standard Test Methods for Hookup Wire Insulation
Published By | Publication Date | Number of Pages |
ASTM | 2004 | 41 |
ASTM D3032-04
Historical Standard: Standard Test Methods for Hookup Wire Insulation
ASTM D3032
Scope
1.1 These test methods cover procedures for testing hookup wire.
1.2 For the purposes of these test methods, hookup wire insulation includes all components of the insulation system used on single insulated conductors or an assembly of single insulated conductors such as a cable bundle and harness or flat ribbon cable. The insulating materials include not only the primary insulation over the conductor, but also insulating jackets over shielded constructions.
1.3 The test procedures and their locations are as follows:
1.4 The values stated in SI are the standard. The values given in parentheses are for information only.
1.5 sibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precaution statements, see 12.2.1, 12.4.1.8, 18.1.3 and Note 17 and 25.4.
Keywords
ambient temperature; arcing; arc-propagation; arc-tracking; atmospheric pressure; breakdown voltage; cable; circuit breakers; current limiting; cuts; degradation; dropping apparatus; dry-arcing; electrical insulation; electrolyte; extinction voltage; flame propagation; flame spread; flame test; flammability; hookup wire; insulation thickness; moisture; open-circuit detection; partial discharge; power supply; safe voltage; scintillation; service condition; short-circuit detection; shutdown equipment; track resistant; tracking; transportation vehicles; voltage rating; wet; wire abrasion; wire chafing; wire insulation
ICS Code
ICS Number Code 29.060.10 (Wires)
DOI: 10.1520/D3032-04
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents |
2 | Terminology Sampling Dielectric Breakdown Voltage |
3 | Insulation Resistance Surface Resistance |
4 | Voltage Withstand Test FIG. 1 FIG. 2 |
5 | Capacitance of Shielded, Single-Conductor Hookup Cable Capacitance and Capacitance Unbalance of Shielded Two-Conductor Hookup Cable |
6 | Capacitance of Unshielded Twisted Pair Hookup Wire Capacitance and Dissipation Factor of Hookup Wire Insulation by the Mercury U-Tube Method FIG. 3 |
7 | FIG. 4 |
8 | Insulation-Continuity Proof Tests |
10 | Relative Thermal End Point Time and Temperature Index |
11 | FIG. 5 |
14 | Dimensions FIG. 6 |
15 | FIG. 7 |
16 | Concentricity Tensile Properties FIG. 8 FIG. 9 FIG. 10 FIG. 11 FIG. 12 |
17 | Flame Tests FIG. 13 |
18 | FIG. 14 |
19 | FIG. 15 |
21 | FIG. 16 FIG. 17 |
22 | Bondability of Insulation to Potting Compounds TABLE 1 |
23 | Crush Resistance TABLE 2 |
24 | Axial Stability (Longitudinal Change) After Thermal Exposure |
25 | Dynamic Cut-Through |
26 | Fluid Immersion FIG. 18 FIG. 19 |
28 | High Temperature Shock Partial Discharge (Corona) Inception and Extinction Voltage TABLE 3 |
29 | Cold Bend Test FIG. 20 |
30 | Strip Force Test TABLE 4 |
31 | Wet Arc-Tracking TABLE 5 |
32 | FIG. 21 |
33 | Dry-Arc Tracking FIG. 22 FIG. 23 |
34 | FIG. 24 |
35 | FIG. 25 FIG. 26 FIG. 27 |
36 | Keywords A1. POWER SUPPLY A1.1 A1.2 A1.3 FIG. 28 FIG. 29 |
37 | A1.4 A2. VOLTAGE RATING OF HOOK-UP WIRE A2.1 A2.2 A2.3 A2.4 A2.5 |
38 | X1. ADDITIONAL MANDREL DIAMETERS AND WEIGHTS FOR SECTION 14.4.4 X2. DATA FROM INTERLABORATORY STUDY ON BONDABILITY TEST METHOD X2.1 X2.2 |
39 | X3. DATA FROM INTERLABORATORY STUDY ON THE VERTICAL FLAME TEST X3.1 X3.2 X4. COMMONLY USED FLUIDS FOR IMMERSION TESTING X4.1 X4.2 X4.3 X4.4 X5. MANDREL SIZES AND WEIGHTS FOR FLUID IMMERSION WRAP TEST X6. FACTORS AFFECTING WET ARC-TRACKING OF INSULATED WIRE X6.1 TABLE X5.1 |
40 | X6.2 X6.3 X6.4 X6.5 |