D3049-89(2003) Standard Test Method for Synthetic Anionic Ingredient by Cationic Titration

Published By Publication Date Number of Pages
ASTM 2003 4
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 This test method covers the determination of the amount of synthetic anionic ingredient in a surfactant by direct titration with a standardized cationic reagent. The test method is a simple and convenient means for the quantitative estimation of the anionic material. The end point is detected by the transfer of a colored complex from an organic solvent phase to an aqueous phase. The colored complex is formed by the addition of a solution of dye to a solution of the anionic surfactant. This complex is soluble in the organic-solvent phase and insoluble in the aqueous phase. When this solution is titrated with a standardized solution of a cationic reagent, the dye is displaced from the colored complex and, being water-soluble, migrates to the aqueous phase. Therefore, a cationic titrating solution that has been standardized against a characterized anionic agent can be used to analyze for other anionics of known molecular mass.

1.2 This test method is applicable to alkylaryl sulfonates, alkyl sulfonates, alkyl sulfates and hydroxy-sulfates, alkylphenol- and fatty alcohol ethoxy-sulfates and dialkylsulfosuccinates. It applies to active materials containing one hydrophilic group per molecule.

1.3 The analytical procedures appear in the following order:

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. A precautionary statement appears in Section 7. Material Safety Data Sheets are available for reagents and materials. Review them for hazards prior to usage.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Summary of Test Method
Significance and Use
Interferences
2 Reagents
Safety Precaution
Primary Standard
3 Preparation of the Mixed Indicator Solution
Preparation of 0.004 M Hyamine 1622 Solution
Standardization of Hyamine 1622 Solution
4 General Procedure for Anionic-Active Material
Report
Precision and Bias
Keywords
TABLE 1
ASTM-D3049 2003