D5093-02(2008) Standard Test Method for Field Measurement of Infiltration Rate Using Double-Ring Infiltrometer with Sealed-Inner Ring

Published By Publication Date Number of Pages
ASTM 2008 7
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM D5093-02-Reapproved2008

Historical Standard: Standard Test Method for Field Measurement of Infiltration Rate Using Double-Ring Infiltrometer with Sealed-Inner Ring

ASTM D5093

Scope

1.1 This test method describes a procedure for measuring the infiltration rate of water through in-place soils using a double-ring infiltrometer with a sealed inner ring.

1.2 This test method is useful for soils with infiltration rates in the range of 1 × 107 m/s to 1 × 1010 m/s. When infiltration rates 1 × 107 m/s are to be measured Test Method D 3385 shall be used.

1.3 All observed and calculated values shall conform to the guide for significant digits and rounding established in Practice D 6026.

1.3.1 The method used to specify how data are collected, calculated, or recorded in this standard is not directly related to the accuracy to which the data can be applied in design or other uses, or both. How one applies the results obtained using this standard is beyond its scope.

1.4 This test method provides a direct measurement of infiltration rate, not hydraulic conductivity. Although the units of infiltration rate and hydraulic conductivity are similar, there is a distinct difference between these two quantities. They cannot be directly related unless the hydraulic boundary conditions, such as hydraulic gradient and the extent of lateral flow of water are known or can be reliably estimated.

1.5 This test method can be used for natural soil deposits, recompacted soil layers, and amended soils such as soil bentonite and soil lime mixtures.

1.6 The values stated in SI units are to be regarded as standard. The values in parentheses are for information only.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

double ring infiltration; in-place infiltration; soil moisture infiltrometer; Clay liners; Double-ring infiltrometers; Field testing–soil; Fine-grained soil; Flow and flow rate–water; Infiltration rate; Soil; Soil-moisture analysis

ICS Code

ICS Number Code 65.060.35 (Irrigation and drainage equipment)

DOI: 10.1520/D5093-02R08

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
Summary of Test Method
2 Significance and Use
Apparatus
FIG. 1
FIG. 2
3 Test Site
Procedure
FIG. 3
5 Calculation
6 Report
Precision and Bias
Keywords
FIG. 4
FIG. 5