ASTM-D5093 2015
$40.63
D5093-15e1 Standard Test Method for Field Measurement of Infiltration Rate Using Double-Ring Infiltrometer with Sealed-Inner Ring
Published By | Publication Date | Number of Pages |
ASTM | 2015 | 7 |
ASTM D5093-15e1
Withdrawn Standard: Standard Test Method for Field Measurement of Infiltration Rate Using Double-Ring Infiltrometer with Sealed-Inner Ring (Withdrawn 2024)
ASTM D5093
Scope
1.1 This test method describes a procedure for measuring the infiltration rate of water through in-place soils using a double-ring infiltrometer with a sealed inner ring.
1.2 This test method is useful for soils with infiltration rates in the range of 1 × 10−5 cm/s to 1 × 10−8 cm/s. When infiltration rates ≥1 × 10−5 cm/s are to be measured Test Method D3385 shall be used.
1.3 All observed and calculated values shall conform to the guide for significant digits and rounding established in Practice D6026.
1.3.1 The method used to specify how data are collected, calculated, or recorded in this standard is not directly related to the accuracy to which the data can be applied in design or other uses, or both. How one applies the results obtained using this standard is beyond its scope.
1.4 This test method provides a direct measurement of infiltration rate, not hydraulic conductivity. Although the units of infiltration rate and hydraulic conductivity are similar, there is a distinct difference between these two quantities. They cannot be directly related unless the hydraulic boundary conditions, such as hydraulic gradient and the extent of lateral flow of water are known or can be reliably estimated.
1.5 This test method can be used for natural soil deposits, recompacted soil layers, and amended soils such as soil bentonite and soil lime mixtures.
1.6 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Keywords
double ring infiltration; in-place infiltration; soil moisture infiltrometer ;
ICS Code
ICS Number Code 65.060.35 (Irrigation and drainage equipment)
DOI: 10.1520/D5093-15E01