ASTM-D5704 2007
$44.96
D5704-07 Standard Test Method for Evaluation of the Thermal and Oxidative Stability of Lubricating Oils Used for Manual Transmissions and Final Drive Axles
Published By | Publication Date | Number of Pages |
ASTM | 2007 | 17 |
1.1 This test method is commonly referred to as the L-60-1 test. It covers the oil-thickening, insolubles-formation, and deposit-formation characteristics of automotive manual transmission and final drive axle lubricating oils when subjected to high-temperature oxidizing conditions.
1.2 The values stated in inch-pound units are to be regarded as the standard except for the catalyst weight loss and oil weight measurements, for which the unit is gram; the oil volume, for which the unit is millilitre; the alternator output, for which the unit is watt; and the air flow, for which the unit is milligram per minute. The other SI values, which are in parentheses, are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific warning information is given in Sections 7 and 8 and Annex A3.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology |
2 | Summary of Test Method Significance and Use Apparatus |
3 | Reagents and Materials Preparation of Apparatus |
5 | Calibration and Standardization |
6 | Procedure for Conducting the Test |
7 | Procedure for Determination of Catalyst Weight Loss Procedure for Evaluation of Drain Oil Calculation TABLE 1 |
8 | Report Precision and Bias TABLE 2 |
9 | Keywords A1. DIAGRAM OF TEST APPARATUS A1.1 FIG. A1.1 |
10 | A2. EXPLODED VIEW OF GEAR CASE ASSEMBLY A2.1 FIG. A2.1 |
11 | A3. WARNING STATEMENTS A3.1 A3.2 Physical Hazards A4. THE ROLE OF THE TEST MONITORING CENTER A4.1 A4.2 Information Letters A4.3 A4.4 |
12 | A5. L-60-1 TEST REPORT FORMS and DATA DICTIONARY A5.1 A6. CORRECTIONS TO NON-REFERENCE OIL TESTS FOR INDUSTRY SEVERITY A6.1 A6.2 A6.3 A6.4 A6.5 A7. ALTERNATOR LOAD CIRCUIT A7.1 |
13 | A8. CONTROL CHART TECHNIQUE FOR SEVERITY ADJUSTMENT (SA) A8.1 FIG. A7.1 |
14 | A8.2 A8.3 A8.4 A8.5 |
15 | A9. GEAR HOLDER APPARATUS A9.1 FIG. A9.1 |
16 | A10. L-60-1 VARNISH RATING PROCEDURE A10.1 A10.2 A10.3 A10.4 A10.5 A10.6 A10.7 A10.8 A10.9 A10.10 FIG. A9.2 |