D7007-09 Standard Practices for Electrical Methods for Locating Leaks in Geomembranes Covered with Water or Earth Materials

Published By Publication Date Number of Pages
ASTM 2009 12
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 These practices describe standard procedures for using electrical methods to locate leaks in geomembranes covered with water or earth materials containing moisture.

1.2 These practices are intended to ensure that leak location surveys are performed with demonstrated leak detection capability. To allow further innovations, and because various leak location practitioners use a wide variety of procedures and equipment to perform these surveys, performance-based operations are used that specify the minimum leak detection performance for the equipment and procedures.

1.3 These practices require that the leak location equipment, procedures, and survey parameters used are demonstrated to result in an established minimum leak detection sensitivity. The survey shall then be conducted using the demonstrated equipment, procedures, and survey parameters.

1.4 Separate procedures are given for leak location surveys for geomembranes covered with water and for geomembranes covered with earth materials. Separate procedures are given for leak detection sensitivity tests using actual and artificial leaks.

1.5 Leak location surveys can be used on geomembranes installed in basins, ponds, tanks, ore and waste pads, landfill cells, landfill caps, and other containment facilities. The procedures are applicable for geomembranes made of materials such as polyethylene, polypropylene, polyvinyl chloride, chlorosulfonated polyethylene, bituminous material, and other electrically-insulating materials.

1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.7 Warning The electrical methods used for geomembrane leak location could use high voltages, resulting in the potential for electrical shock or electrocution. This hazard might be increased because operations might be conducted in or near water. In particular, a high voltage could exist between the water or earth material and earth ground, or any grounded conductor. These procedures are potentially VERY DANGEROUS, and can result in personal injury or death. The electrical methods used for geomembrane leak location should be attempted only by qualified and experienced personnel. Appropriate safety measures must be taken to protect the leak location operators as well as other people at the site.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
2 Summary of the Leak Location Methods
FIG. 1
3 Significance and Use
General Leak Location Survey Procedures
FIG. 2
4 Leak Location Survey Procedures for Surveys with Water Covering the Geomembrane
TABLE 1
5 Leak Location Survey Procedures for Surveys with Earth Material Covering the Geomembrane
TABLE 2
6 Reporting Requirements
Keywords
A1. PROCEDURES FOR LEAK DETECTION SENSITIVITY TEST FOR SURVEYS WITH WATER COVERING THE GEOMEMBRANE USING AN ARTIFICIAL LEAK
A1.1 Artificial Leak
A1.2
A1.3
A1.4
A1.5
7 A1.6
A1.7
A1.8 Leak Detection Sensitivity Test
A1.9
FIG. A1.1
8 A2. PROCEDURES FOR LEAK DETECTION SENSITIVITY TEST FOR SURVEYS WITH WATER COVERING THE GEOMEMBRANE USING AN ACTUAL LEAK
A2.1
A2.2
A2.3 Leak Detection Sensitivity Test
A2.4
A3. PROCEDURES FOR LEAK DETECTION SENSITIVITY TEST FOR SURVEYS WITH EARTH MATERIAL COVERING THE GEOMEMBRANE USING AN ARTIFICIAL LEAK
A3.1 Artificial Leak
A3.2
FIG. A3.1
9 A3.3
A3.4
A3.5 Leak Detection Sensitivity Test
FIG. A3.2
10 FIG. A3.3
11 A4. PROCEDURES FOR LEAK DETECTION SENSITIVITY TEST FOR SURVEYS WITH EARTH MATERIAL COVERING THE GEOMEMBRANE USING AN ACTUAL LEAK
A4.1
A4.2 Actual Leak
A4.3
A4.4 Leak Detection Sensitivity Test