ASTM-E2304 2011

$40.63

E2304-03(2011) Standard Practice for Use of a LiF Photo-Fluorescent Film Dosimetry System

Published By Publication Date Number of Pages
ASTM 2011 8
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

ASTM E2304-03-Reapproved2011

Withdrawn Standard: Standard Practice for Use of a LiF Photo-Fluorescent Film Dosimetry System (Withdrawn 2020)

ASTM E2304

Scope

1.1 This practice covers the handling, testing, and procedure for using a lithium fluoride (LiF)-based photo-fluorescent film dosimetry system to measure absorbed dose (relative to water) in materials irradiated by photons or electrons. Other alkali halides that may also exhibit photofluorescence (for example, NaCl, NaF, and KCl) are not covered in this practice. Although various alkali halides have been used for dosimetry for years utilizing thermoluminescence, the use of photoluminescence is relatively new.

1.2 This practice applies to photo-fluorescent film dosimeters (referred hereafter as photo-fluorescent dosimeters) that can be used within part or all of the following ranges:

1.2.1 Absorbed dose range of 5 Ɨ 10-2 to 3 Ɨ 102 kGy (1-3).

1.2.2 Absorbed dose rate range of 0.3 to 2 Ɨ 104 Gy/s (2-5)).

1.2.3 Radiation energy range for photons of 0.05 to 10 MeV (2).

1.2.4 Radiation energy range for electrons of 0.1 to 10 MeV (2).

1.2.5 Radiation temperature range of -20 to +60Ā°C (6,7).

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

absorbed dose; calibration facility; dosimeter; dosimeter calibration; dosimetry system; electron beam; food irradiation; gamma ray; ionizing radiation; photo-fluorescent dosimeter; quality assurance; radiation processing; routine dosimeter

ICS Code

ICS Number Code 17.240 (Radiation measurements)

DOI: 10.1520/E2304-03R11

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
2 Terminology
3 Significance and Use
FIG. 1
4 Apparatus
Performance Check of Instrumentation
Calibration of the Dosimetry System
5 Procedure
6 Characterization of Each Stock of Dosimeters
7 Application of Dosimetry System
Minimum Documentation Requirements
Measurement Uncertainty
Keywords
REFERENCES