ASTM-E459 2022

$37.38

E459-22 Standard Test Method for Measuring Heat Transfer Rate Using a Thin-Skin Calorimeter

Published By Publication Date Number of Pages
ASTM 2022
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM E459-22

Active Standard: Standard Test Method for Measuring Heat Transfer Rate Using a Thin-Skin Calorimeter

ASTM E459

Scope

1.1 This test method covers the design and use of a thin metallic calorimeter for measuring heat transfer rate (also called heat flux). Thermocouples are attached to the unexposed surface of the calorimeter. A one-dimensional heat flow analysis is used for calculating the heat transfer rate from the temperature measurements. Applications include aerodynamic heating, laser and radiation power measurements, and fire safety testing.

1.2 Advantages: 

1.2.1 Simplicity of Construction—The calorimeter may be constructed from a number of materials. The size and shape can often be made to match the actual application. Thermocouples may be attached to the metal by spot, electron beam, or laser welding.

1.2.2 Heat transfer rate distributions may be obtained if metals with low thermal conductivity, such as some stainless steels or Inconel 600, are used.

1.2.3 The calorimeters can be fabricated with smooth surfaces, without insulators or plugs and the attendant temperature discontinuities, to provide more realistic flow conditions for aerodynamic heating measurements.

1.2.4 The calorimeters described in this test method are relatively inexpensive. If necessary, they may be operated to burn-out to obtain heat transfer information.

1.3 Limitations: 

1.3.1 At higher heat flux levels, short test times are necessary to ensure calorimeter survival.

1.3.2 For applications in wind tunnels or arc-jet facilities, the calorimeter must be operated at pressures and temperatures such that the thin-skin does not distort under pressure loads. Distortion of the surface will introduce measurement errors.

1.3.3 Interpretation of the heat flux estimated may require additional analysis if the thin-skin calorimeter configuration is different from the test specimen.

1.4 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4.1 Exception—The values given in parentheses are for information only.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Keywords

calorimeter; convective heat flux; data acquisition system; heat transfer distribution; heat transfer rate; net heat flux; radiative heat flux; thermocouples; thin-skin calorimeter; uncertainty;

ICS Code

ICS Number Code 17.200.10 (Heat. Calorimetry)

DOI: 10.1520/E0459-22