Historical Standard: Standard Test Method for Water Penetration and Leakage Through Masonry
ASTM E514
Scope
1.1 This laboratory test method provides a procedure for determining the resistance to water penetration and leakage through unit masonry subjected to wind-driven rain.
1.2 The values stated in SI units are to be regarded as standard. The values in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific hazard statement, see Section 6.
Keywords
air-pressure; laboratory test; manometer; masonry; simulated wind driven rain; test chamber; water penetration; water spray pipe; Leak testing–building constructions/materials; Masonry assemblages; Water penetration–masonry materials/applications
ICS Code
ICS Number Code 91.080.30 (Masonry)
DOI: 10.1520/E0514-08
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology Significance and Use Apparatus |
2 | FIG. 1 FIG. 2 |
3 | Hazards Temperature and Humidity Conditions Test Specimens Procedure |
4 | Record of Observation Retesting Report Precision and Bias Keywords |