Shopping Cart

No products in the cart.

ASTM-E534 2008

$40.63

E534-08 Standard Test Methods for Chemical Analysis of Sodium Chloride

Published By Publication Date Number of Pages
ASTM 2008 7
Guaranteed Safe Checkout
Categories: , ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

1.1 These test methods cover the chemical analyses usually required for sodium chloride.

1.2 The analytical procedures appear in the following sections:

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.5 Review the current material safety data sheets (MSDS) for detailed information concerning toxicity, first-aid procedures, handling, and safety precautions.

5.1 This test method covers preparation of a sample that will be as representative as possible of the entire bulk quantity. The results of any analysis pertain only to the sample used.

10.1 This test method determines free moisture in the salt over a concentration range from 0.00 to 0.04 %. It does not determine occluded moisture trapped within the salt crystals. The procedure is based on weight loss after a sample is heated to volatize moisture.

17.1 This gravimetric method determines only the amount of insolubles present in sodium chloride which will not dissolve in water.

25.1 This test method covers the EDTA titrimetric determination of calcium and magnesium and the EDTA titrimetric determination of calcium. The magnesium content is determined by difference.

32.1 This test method covers the gravimetric determination of the sulfate content of sodium chloride.

39.1 Analyses should be reported on a dry basis. If analyses are on an as received sample, correction should be made by converting to a dry basis. Sodium chloride purity is determined by subtracting the total percentage of impurities from 100. Moisture should be reported as a separate value.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Significance and Use
Reagents
Scope
Apparatus
Reagents
Rock and Solar Salt Stock Solutions
2 Evaporated and Purified Salt Stock Solutions
Scope
Apparatus
Procedure, Rock and Solar Salt
Procedure, Evaporated and Purified Evaporated Salt
Calculation
Report
Precision and Bias
Scope
Apparatus
TABLE 1
3 Reagents
Procedure, Rock and Solar Salts
Procedure, Evaporated and Purified Evaporated Salts
Calculation
Report
Precision and Bias
TABLE 2
4 Scope
Apparatus
Reagents
Procedure
Calculation
Report
Precision and Bias
TABLE 3
5 Scope
Apparatus
Reagents
Procedure
TABLE 4
6 Calculation
Report
Precision and Bias
Scope
Procedure
Conversion Factors
Keywords
TABLE 5
ASTM-E534 2008