ASTM-F1308:2003 Edition
$40.63
F1308-98(2003) Standard Test Method for Quantitating Volatile Extractables in Microwave Susceptors Used for Food Products
Published By | Publication Date | Number of Pages |
ASTM | 2003 | 5 |
ASTM F1308-98-Reapproved2003
Historical Standard: Standard Test Method for Quantitating Volatile Extractables in Microwave Susceptors Used for Food Products
ASTM F1308
Scope
1.1 This test method covers complete microwave susceptors.
1.2 This test method covers a procedure for quantitating volatile compounds whose identity has been established and which are evolved when a microwave susceptor sample is tested under simulated use conditions.
1.3 This test method was collaboratively evaluated with a variety of volatile compounds (see statistical evaluation). For compounds other than those evaluated, the analyst should determine the sensitivity and reproducibility of the method by carrying out appropriate spike and recovery studies. The analyst is referred to Practice E 260 for guidance.
1.4 For purposes of verifying the identity of or identifying unknown volatile compounds, the analyst is encouraged to incorporate techniques such as gas chromatography/mass spectroscopy, gas chromatography/infrared spectroscopy, or other techniques in conjunction with this test method.
1.5 A sensitivity level of approximately 0.025 g/in. is achievable for the compounds studied in . Where other compounds are being quantitated and uncertainty exists over method sensitivity, the analyst is referred to Practice E 260 for procedures on determining sensitivity of chromatographic methods.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific safety hazards warnings are given in 10.2, 11.1, and 11.6.
Keywords
extractables; volatile; quantitation; in microwave susceptors; fluroptic thermometry; gas chromatography; static headspace; microwave susceptors; microwave suseptors, valatile extractables in; susceptors; microwave; volatile extractables; quantitation; in microwave susceptors
ICS Code
ICS Number Code n/a
DOI: 10.1520/F1308-98R03
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology TABLE 1 |
2 | Summary of Test Method Significance and Use Interferences Apparatus and Reagents |
3 | Instrument Setup Sampling |
4 | Calibration Procedure Calculation Precision and Bias |
5 | Keywords TABLE 2 |