Shopping Cart

No products in the cart.

AWC NDS withCommentary 2012

$81.25

National Design Specification (NDS) for Wood Construction with Commentary

Published By Publication Date Number of Pages
AWC 2012 298
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ANSI/AWC NDS-2012, was approved as an ANSI American National Standard on August 15, 2011. The 2012 NDS was developed by the American Wood Council’s (AWC) Wood Design Standards Committee and has been approved by ANSI as an American National Standard. The 2012 NDS is referenced in the 2012 International Building Code

PDF Catalog

PDF Pages PDF Title
1 ASD/LRFD NDS
3 Title
4 COPYRIGHT
5 FOREWORD
7 TABLE OF CONTENTS FOR THE NDS
8 TABLE OF CONTENTS FOR THE NDS COMMENTARY
10 LIST OF TABLES FOR THE NDS
13 LIST OF FIGURES FOR THE NDS
LIST OF TABLES FOR THE NDS COMMENTARY
14 LIST OF FIGURES FOR THE NDS COMMENTARY
15 1 GENERAL REQUIREMENTS FOR STRUCTURAL DESIGN
16 1.1 Scope
1.2 General Requirements
1.3 Standard as a Whole
1.4 Design Procedures
17 1.5 Specifications and Plans
1.6 Notation
23 2 DESIGN VALUES FOR STRUCTURAL MEMBERS
24 2.1 General
2.2 Reference Design Values
2.3 Adjustment of Reference Design Values
27 3 DESIGN PROVISIONS AND EQUATIONS
28 3.1 General
29 3.2 Bending Members — General
3.3 Bending Members — Flexure
31 3.4 Bending Members — Shear
33 3.5 Bending Members — Deflection
34 3.6 Compression Members — General
35 3.7 Solid Columns
36 3.8 Tension Members
3.9 Combined Bending and Axial Loading
37 3.10 Design for Bearing
39 4 SAWN LUMBER
40 4.1 General
41 4.2 Reference Design Values
42 4.3 Adjustment of Reference Design Values
45 4.4 Special Design Considerations
47 5 STRUCTURAL GLUED LAMINATED TIMBER
48 5.1 General
49 5.2 Reference Design Values
50 5.3 Adjustment of Reference Design Values
53 5.4 Special Design Considerations
57 6 ROUND TIMBER POLES AND PILES
58 6.1 General
6.2 Reference Design Values
59 6.3 Adjustment of Reference Design Values
63 7 PREFABRICATED WOOD I- JOISTS
64 7.1 General
7.2 Reference Design Values
7.3 Adjustment of Reference Design Values
66 7.4 Special Design Considerations
67 8 STRUCTURAL COMPOSITE LUMBER
68 8.1 General
8.2 Reference Design Values
8.3 Adjustment of Reference Design Values
70 8.4 Special Design Considerations
71 9 WOOD STRUCTURAL PANELS
72 9.1 General
9.2 Reference Design Values
73 9.3 Adjustment of Reference Design Values
74 9.4 Design Considerations
75 10 MECHANICAL CONNECTIONS
76 10.1 General
77 10.2 Reference Design Values
10.3 Adjustment of Reference Design Values
85 11 DOWEL-TYPE FASTENERS
86 11.1 General
88 11.2 Reference Withdrawal Design Values
92 11.3 Reference Lateral Design Values
98 11.4 Combined Lateral and Withdrawal Loads
11.5 Adjustment of Reference Design Values
101 11.6 Multiple Fasteners
127 12 SPLIT RING AND SHEAR PLATE CONNECTORS
128 12.1 General
129 12.2 Reference Design Values
135 12.3 Placement of Split Ring and Shear Plate Connectors
141 13 TIMBER RIVETS
142 13.1 General
13.2 Reference Design Values
144 13.3 Placement of Timber Rivets
153 14 SHEAR WALLS AND DIAPHRAGMS
154 14.1 General
155 15 SPECIAL LOADING CONDITIONS
156 15.1 Lateral Distribution of a Concentrated Load
15.2 Spaced Columns
158 15.3 Built-Up Columns
161 15.4 Wood Columns with Side Loads and Eccentricity
163 16 FIRE DESIGN OF WOOD MEMBERS
164 16.1 General
16.2 Design Procedures for Exposed Wood Members
165 16.3 Wood Connections
167 APPENDIX
168 Appendix A (Non-mandatory) Construction and Design Practices
170 Appendix B (Non-mandatory) Load Duration (ASD Only)
172 Appendix C (Non-mandatory) Temperature Effects
173 Appendix D (Non-mandatory) Lateral Stability of Beams
174 Appendix E (Non-mandatory) Local Stresses in Fastener Groups
179 Appendix F (Non-mandatory) Design for Creep and Critical Deflection Applications
181 Appendix G (Non-mandatory) Effective Column Length
182 Appendix H (Non-mandatory) Lateral Stability of Columns
183 Appendix I (Non-mandatory) Yield Limit Equations for Connections
186 Appendix J (Non-mandatory) Solution of Hankinson Formula
189 Appendix K (Non-mandatory) Typical Dimensions for Split Ring and Shear Plate Connectors
190 Appendix L (Non-mandatory) Typical Dimensions for Dowel-Type Fasteners and Washers
194 Appendix M (Non-mandatory) Manufacturing Tolerances for Rivets and Steel Side Plates for Timber Rivet Connections
195 Appendix N (Mandatory) Load and Resistance Factor Design (LRFD)
197 REFERENCES
201 NDS COMMENTARY
FOREWORD TO THE NDS COMMENTARY
202 C1 GENERAL REQUIREMENTS FOR STRUCTURAL DESIGN
C1.1 Scope
C1.2 General Requirements
203 C1.3 Standard as a Whole
C1.4 Design Procedures
204 C1.5 Specifications and Plans
205 C2 DESIGN VALUES FOR STRUCTURAL MEMBERS
C2.1General
C2.3 Adjustment of Reference Design Values
209 C3 DESIGN PROVISIONS AND EQUATIONS
C3.1 General
210 C3.2 Bending Members – General
C3.3 Bending Members – Flexure
211 C3.4 Bending Members – Shear
212 C3.5 Bending Members – Deflection
213 C3.6 Compression Members – General
214 C3.7 Solid Columns
215 C3.8 Tension Members
216 C3.9 Combined Bending and Axial Loading
217 C3.10 Design for Bearing
218 C4 SAWN LUMBER
C4.1 General
220 C4.2 Reference Design Values
222 C4.3 Adjustment of Reference Design Values
224 C4.4 Special Design Considerations
226 C5 STRUCTURAL GLUED LAMINATED TIMBER
C5.1 General
228 C5.2 Reference Design Values
230 C5.3 Adjustment of Reference Design Values
232 C5.4 Special Design Considerations
234 C6 ROUND TIMBER POLES AND PILES
C6.1 General
235 C6.2 Reference Design Values
236 C6.3 Adjustment of Reference Design Values
238 C7 PREFABRICATED WOOD I-JOISTS
C7.1 General
C7.2 Reference Design Values
239 C7.3 Adjustment of Reference Design Values
240 C7.4 Special Design Considerations
242 C8 STRUCTURAL COMPOSITE LUMBER
C8.1 General
C8.2 Reference Design Values
C8.3 Adjustment of Reference Design Values
243 C8.4 Special Design Considerations
244 C9 WOOD STRUCTURAL PANELS
C9.1 General
245 C9.2 Reference Design Values
247 C9.3 Adjustment of Reference Design Values
248 C9.4 Design Considerations
250 C10 MECHANICAL CONNECTIONS
C10.1 General
251 C10.2 Reference Design Values
252 C10.3 Adjustment of Reference Design Values
254 C11 DOWEL-TYPE FASTENERS
C11.1 General
256 C11.2 Reference Withdrawal Design Values
259 C11.3 Reference Lateral Design Values
261 C11.4 Combined Lateral and Withdrawal Loads
262 C11.5 Adjustment of Reference Design Values
265 C11.6 Multiple Fasteners
266 C12 SPLIT RING AND SHEAR PLATE CONNECTORS
C12.1 General
267 C12.2 Reference Design Values
268 C12.3 Placement of Split Ring and Shear Plate Connectors
271 C13 TIMBER RIVETS
C13.1 General
272 C13.2 Reference Design Values
274 C13.3 Placement of Timber Rivets
275 C14 SHEAR WALLS AND DIAPHRAGMS
C14.1 General
276 C15 SPECIAL LOADING CONDITIONS
C15.1 Lateral Distribution of a Concentrated Load
277 C15.2 Spaced Columns
279 C15.3 Built-Up Columns
280 C15.4 Wood Columns with Side Loads and Eccentricity
282 C16 FIRE DESIGN OF WOOD MEMBERS
C16.1 General
284 C16.2 Design Procedures for Exposed Wood Members
287 REFERENCES
298 Back Cover
AWC NDS withCommentary 2012
$81.25