AWWA Manual M14 4thEdition 2015
$86.67
AWWA Manual M14 Backflow Prevention and Cross-Connection Control: Recommended Practices, Fourth Edition
Published By | Publication Date | Number of Pages |
AWWA | 2015 | 221 |
A cross-connection is an actual or potential connection between any part of a potable water system and any other environment that contains other substances that would allow such substances to enter the potable water system. Cross-connection control programs are intended to reduce the risk of contamination or pollution of the public water system. This fourth edition of AWWA Manual M14, Backflow Prevention and Cross-Connection Control, provides both technical and general guidance on the recommended procedures and practices for developing, operating, and maintaining a cross-connection control and backflow prevention program. This edition includes a new chapter on conducting a cross-connection control survey and expands the discussions on assessing the risks and preventing backflow. A greatly expanded appendix details how to test most backflow-prevention devices. Other issues covered include backflow prevention principles, assembly, application, installation, and maintenance; health and legal concerns; and detailed information on potential and real hazards. This manual is intended for use by all professionals charged with protecting the public water supply with proper backflow prevention and cross-connection control programs.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Cover |
3 | Copyright |
4 | Contents |
6 | List of Figures |
8 | List of Tables |
10 | Preface |
12 | Acknowledgments |
14 | Dedication |
16 | Metric Conversions |
18 | Chapter 1 Introduction Purpose of Manual |
19 | Responsibilities |
22 | Health Aspects |
24 | Legal Aspects |
28 | Chapter 2 Backfl ow Prevention Principles Basic Hydraulics |
30 | Types of Backflow |
35 | Assessing Degrees of Hazard |
37 | Assessing Other Risk Factors |
38 | Assessing the Effectiveness of Assemblies and Devices |
40 | Chapter 3 Program Administration |
41 | Developing a Cross-Connection Control Program |
42 | Types of Programs |
45 | Management Programs |
50 | Documentation Human Resources |
52 | Program Administration |
58 | Chapter 4 Backflow Prevention Assembly Application, Installation, and Maintenance |
59 | Means of Preventing Backflow Backflow Prevention Devices |
76 | Method for Controlling Backflow |
78 | Field Testing |
81 | Reference |
82 | Chapter 5 Conducting a Cross-Connection Control Survey |
83 | Authority and Responsibilities Purpose of a Cross-Connection Control Survey |
84 | Assessing the Degree of Hazard Survey Considerations and Concepts |
86 | Conducting the Survey |
91 | Reference |
92 | Chapter 6 Sample Hazards and Proper Protection |
93 | Typical Hazards |
101 | Hazards Posed by a Water Supplier |
106 | Protection for Specific Customers |
108 | References |
110 | Appendix A Example Notices and Letters |
116 | Appendix B Testing Procedures or Methods |
198 | Appendix C Industry Resources |
200 | Appendix D Incidents Tables |
204 | Glossary |
210 | Index |
220 | List of AWWA Manuals |