International Energy Conservation Code: As Amended by the City of Phoenix

Published By Publication Date Number of Pages
AZ 2006 74
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

2006 International Energy Conservation Code fully integrated with the City of Phoenix Amendments.

PDF Catalog

PDF Pages PDF Title
1 INTERNATIONAL ENERGY CONSERVATION CODE® 2006 AS AMENDED BY THE CITY OF PHOENIX
2 COPYRIGHT
3 PREFACE
5 ORDINANCE
6 WELCOME PAGE
7 TABLE OF CONTENTS
9 CHAPTER 1 ADMINISTRATION
SECTION 101 SCOPE AND GENERAL REQUIREMENTS
SECTION 102 MATERIALS, SYSTEMS AND EQUIPMENT
10 TABLE102.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTOR
TABLE102.1.3(2) DEFAULT DOOR U-FACTORS
TABLE102.1.3(3) DEFAULT GLAZED FENESTRATION SHGC
SECTION 103 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGN OR INSULATING SYSTEM
SECTION 104 CONSTRUCTION DOCUMENTS
11 SECTION 105 INSPECTIONS
SECTION 106 VALIDITY
SECTION 107 REFERENCED STANDARDS
13 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
17 CHAPTER 3 CLIMATE ZONES
SECTION 301 CLIMATE ZONES
18 FIGURE 301.1 CLIMATE ZONES
19 TABLE 301.1 CLIMATE ZONES BY STATE, COUNTY AND TERRITORIES
20 TABLE301.1—continued CLIMATEZONESBYSTATE,COUNTYANDTERRITORIES
21 TABLE301.1—continued CLIMATE ZONES BY STATE, COUNTY AND TERRITORIES
22 TABLE301.1—continued CLIMATE ZONES BY STATE, COUNTY AND TERRITORIES
23 TABLE301.1—continued CLIMATE ZONES BY STATE, COUNTY AND TERRITORIES
24 TABLE 301.2 WARM HUMID COUNTIES AND TERRITORIES
25 TABLE 301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS
TABLE 301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS
SECTION 302 DESIGN CONDITIONS
27 CHAPTER 4 RESIDENTIAL ENERGY EFFICIENCY
SECTION 401 GENERAL
SECTION 402 BUILDING THERMAL ENVELOPE
TABLE 402.1.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
28 TABLE 402.1.3 EQUIVALENT U-FACTORSa
TABLE 402.2.4 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE)
30 SECTION 403 SYSTEMS (MANDATORY)
SECTION 404 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE)
32 TABLE 404.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
33 TABLE404.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS—continued
34 TABLE404.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS—continued
35 TABLE 404.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa
37 CHAPTER 5 COMMERCIAL ENERGY EFFICIENCY
SECTION 501 GENERAL
SECTION 502 BUILDING ENVELOPE REQUIREMENTS
38 TABLE 502.2(1) BUILDING ENVELOPE REQUIREMENTS – OPAQUE ASSEMBLIES
39 TABLE 502.2(2) METAL BUILDING ASSEMBLY DESCRIPTIONS
EQUATION 5-1
40 TABLE 502.3 BUILDING ENVELOPE REQUIREMENTS: FENESTRATION
41 SECTION 503 BUILDING MECHANICAL SYSTEMS
42 TABLE 503.2.3(1) UNITARY AIR CONDITIONERS AND CONDENSING UNITS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS
43 TABLE 503.2.3(2) UNITARY AND APPLIED HEAT PUMPS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS
44 TABLE 503.2.3(3) PACKAGED TERMINAL AIR CONDITIONERS AND PACKAGED TERMINALHEAT PUMPS
TABLE 503.2.3(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS
45 TABLE 503.2.3(5) BOILERS, GAS- AND OIL-FIRED, MINIMUM EFFICIENCY REQUIREMENTS
TABLE 503.2.3(6) CONDENSING UNITS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS
46 TABLE 503.2.3(7) WATER CHILLING PACKAGES, MINIMUM EFFICIENCY REQUIREMENTS
47 TABLE 503.2.3(8) COPs AND IPLVs FOR NONSTANDARD CENTRIFUGAL CHILLERS < 150 TONS
48 TABLE 503.2.3(9) COPs AND IPLVs FOR NONSTANDARD CENTRIFUGAL CHILLERS 150 TONS, 300 TONS
49 TABLE 503.2.3(10) COPs AND IPLVs FOR NONSTANDARD CENTRIFUGAL CHILLERS > 300 TONS
TABLE 503.2.3(11) PERFORMANCE REQUIREMENTS FOR HEAT REJECTION EQUIPMENT
51 EQUATION 5-2
52 TABLE 503.2.8 MINIMUM PIPE INSULATIONa (thickness in inches)
TABLE 503.3.1(1) ECONOMIZER REQUIREMENTS
TABLE 503.3.1(2) EQUIPMENT EFFICIENCY PERFORMANCE EXCEPTION FOR ECONOMIZERS
54 SECTION 504 SERVICE WATER HEATING (Mandatory)
55 SECTION 505 ELECTRICAL POWER AND LIGHTING SYSTEMS (Mandatory)
56 TABLE 504.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
58 TABLE 505.5.2 INTERIOR LIGHTING POWER ALLOWANCES
60 TABLE 505.6.2 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS
SECTION 506 TOTAL BUILDING PERFORMANCE
63 CHAPTER 6 REFERENCED STANDARDS
AAMA
AMCA
ANSI
ARI
64 ASHRAE
ASME
ASTM
CSA
CTI
DOE
65 HI
ICC
IESNA
NFRC
66 SMACNA
UL
WDMA
67 INDEX
AZ Phoenix City EnergyCode 2006