BS 4553-1:1998:2005 Edition
$102.76
Specification for 600/1000 V single-phase split concentric electric cables – Cables having PVC insulation
Published By | Publication Date | Number of Pages |
BSI | 2005 | 20 |
This British Standard specifies requirements for construction and gives methods of test for PVC-insulated single-phase split concentric cables for operation on an earthed neutral system at nominal voltages up to and including 1 000 V between phases and 600 V to earth.
The cables specified in this part of BS 4553 have a central phase conductor insulated with PVC and a concentric layer comprising bare copper wires (earth continuity conductor) and copper wires covered with extruded polymer (neutral conductor). The cables are intended for use in fixed installations in industrial areas, buildings and similar applications. They are suitable for use in situations where the combination of ambient temperature and temperature rise due to loading current results in a conductor temperature not exceeding 70 °C, and for a maximum short-circuit conductor temperature of 160 °C.
Guidance concerning selection, installation and usage is given in Annex A, Annex B, and Annex J respectively.
Construction requirements and methods of tests for cables intended for use in fixed installations in industrial areas, buildings and similar applications. For use where current loading gives conductor temperature rise not exceeding 70°C and where the maximum short circuit conductor temperature is 160°C.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | BRITISH STANDARD |
2 | Committees responsible for this British Standard |
3 | Contents |
5 | 1 Scope 2 Normative references 3 Definitions rated voltage rated voltage U maximum voltage |
6 | nominal value approximate value type tests (symbol T) sample tests (symbol S) routine tests (symbol R) tests after installation 4 Voltage designation 5 Phase conductor |
7 | 6 Insulation 6.1 General 6.2 Thickness of insulation 6.3 Spark testing of insulation 7 Identification of phase core 7.1 General 7.2 Clarity and durability 8 Bedding 9 Concentric layer 9.1 Neutral conductor |
8 | 9.2 Earth continuity conductor 9.3 String separators 9.4 Application of concentric layer 10 Binders 11 Oversheath 11.1 General 11.2 Thickness of oversheath 11.3 Spark testing of oversheath 12 Cable marking 12.1 External marking |
9 | 12.2 Identification of year of manufacture 12.3 The mark of an approval organization 12.4 Additional marking 13 End sealing 14 Schedule of tests |
10 | 15 Test conditions 15.1 Ambient temperature 15.2 Frequency and waveform of power frequency test voltages 16 Routine tests 16.1 General 16.2 Conductor resistance 16.3 Voltage tests on completed cables 16.4 Insulation resistance 17 Sample tests 17.1 General 17.2 Flame propagation on single cable 18 Type tests 18.1 General 18.2 Compatibility |
11 | Schedule of tests |
12 | Compatibility requirements 600 / 1 000 V PVC-insulated single-phase split concentric cables with stranded copper phase conductors 600 / 1 000 V PVC-insulated single-phase split concentric cables with solid aluminium phase conductors |
13 | (informative) Recommendations for the selection and operation of cables (informative) Recommendations for the selection and operation of cables General Voltage rating Current rating (informative) Recommendations for installation of cables (informative) Recommendations for installation of cables General Minimum temperature during installation |
14 | Minimum installation radius Prevention of moisture ingress Compound filling Tests after installation (informative) Information to be provided with enquiry or order (informative) Information to be provided with enquiry or order |
15 | (normative) Measurement of thickness (normative) Measurement of thickness Sampling Test procedure (normative) Voltage tests on completed cables (normative) Voltage tests on completed cables (normative) Insulation resistance test (normative) Insulation resistance test (normative) Compatibility test (normative) Compatibility test General Test method |
16 | (informative) Notes on type tests (informative) Notes on type tests General Sample selection for type tests Type tests Compatibility test (see 18.2) Change of material Evidence of type testing (informative) Guide to use (informative) Guide to use Aim |
17 | Cable selection and design The products specified in this British Standard are intended to be used for the supply of electrical energy up to the rated voltage indicated on the cable. These cables are intended for use within a nominal power frequency range of 49 Hz to 61 Hz. In addition to the current ratings, due regard should be given to: The possible effects of transient over-voltages should be recognized as they can be detrimental to cables. Environment/application Reasonable protection, appropriate to the choice of cable and the installation conditions, should be provided against mechanical damage. Cables specified in this British Standard contain PVC and when exposed to the effects of external fire will produce harmful smok… Cables may be harmed by exposure to corrosive products or solvent substances, especially petroleum based chemicals or their vapours. Special precautions are required when cables are to be installed in areas classified as hazardous, and reference should be made to BS EN 60079-14. Cables specified in this British Standard are not specifically designed for use: If cables in accordance with this specification are exposed to localized heat, solar radiation or high temperature ambient conditions, or there is a possibility of higher soil thermal resistivity, the current carrying capacity will be reduced. The standard sheathing compounds supplied on these cables do not provide protection against damage by rodents, termites, etc. Loaded cables may have surface temperatures which require protection against accidental contact. Installation Precautions should be taken to avoid mechanical damage to the cables before and during installation. Exceeding the manufacturer’s recommended maximum pulling tensions may result in damage to the cable. If cables are to be installed in ducts, reference should be made to the cable manufacturer for a duct size corresponding to the current rating quoted. The type of jointing and filling compounds employed should be chemically compatible with the cable materials. The cable support system should be such as to avoid damage or danger under normal or fault conditions. |
18 | Cables specified in this British Standard are designed for fixed installations only, e.g. they are not for use as trailing or reeling cables. Repeated over-voltage testing can lead to premature failure of the cable. The selection of cable glands, accessories and any associated tools should take account of all aspects of intended use. Storage and handling of drums Cable drums should be regularly inspected during storage to assess their physical condition. Battens, where applied, should not be removed from drums until the cable is about to be installed. When handling drums, reasonable precautions should be taken to avoid injury. Due regard should be paid to the weight, method and direction of rolling, lifting, protruding nails and splinters. Care should be taken to avoid deterioration of the drums or their becoming a hazard to the general public. The cable manufacturer should be consulted for detailed guidance as to the safe handling of cable drums. Scrap cable incineration |