Shopping Cart

No products in the cart.

BS 6850:2002

$142.49

Gas powered ventilatory resuscitators

Published By Publication Date Number of Pages
BSI 2002 24
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
1 BRITISH STANDARD
2 Committees responsible for this British�Standard
3 Contents
5 1 Scope
2 Normative references
6 3 Terms and definitions
3.1 resuscitator
3.2 gas-powered resuscitator
3.3 automatic resuscitator
3.4 compliance
3.5 resistance
3.6 tidal volume
3.7 minute volume
3.8 frequency
3.9 airway pressure
3.10 pressure-limiting system
3.11 patient connection port
3.12 exhaust port
3.13 demand valve
7 3.14 patient demand valve
3.15 patient valve
3.16 delivered oxygen concentration
3.17 apparatus deadspace (backward leak)
3.18 intermediate hose
3.19 cylinder pressure regulator
4 Classification
5 Cleaning, disinfection and sterilization
6 Connectors
6.1 Patient connection port
6.2 Exhaust port
8 7 Operational requirements
7.1 Ease of operation
7.2 Dismantling and reassembly
7.3 Patient valve function after contamination with vomitus
7.4 Mechanical shock
7.5 Immersion in water
8 Physical requirements
8.1 Dimensions
8.2 Mass
9 9 Performance requirements
9.1 Ventilation performance
9.2 Supplementary oxygen and delivered oxygen concentration
9.3 Resistance to spontaneous breathing
9.4 Deadspace (backward leak)
9.5 Patient demand valves
10 10 Storage and operating conditions
11 Gas supply
11.1 Gas cylinders, cylinder valves and yoke connections
11.2 Contents indication
11.3 Captive valve key
11.4 Cylinder pressure regulators
11.5 Filter
11.6 Intermediate hoses
11.7 Gas supply pressure and connectors
11.8 Container capacity
11 12 Marking
12.1 Operating instructions
12.2 Marking on the resuscitator
12.3 Cylinder connections
13 Information to be provided by the manufacturer
13 Annex A (informative) Recommendations for face masks
Annex B (informative) Recommendations for materials
Annex C (normative) Method of test for patient valve function after contamination with vomitus
C.1 Test material and apparatus
C.2 Procedure
14 Table C.1 – Resistance values of test lung
Table C.2 – Compliance values of test lung
15 Figure C.1 – Schematic diagram of a test lung
16 Annex D (normative) Method of test for tidal volume
D.1 Apparatus
D.2 Procedure
Table D.1 – Test conditions for tidal volume test
17 Figure D.1 – Schematic diagram of an instrumented test lung
18 Annex E (normative) Method of test for pressure limitation
E.1 Apparatus
E.2 Test condition
E.3 Procedure
Annex F (normative) Method of test for delivered oxygen concentration
F.1 Apparatus
F.2 Procedure
19 Annex G (normative) Method of test for resistance to spontaneous breathing
G.1 Apparatus
G.2 Procedure
G.2.1 General
G.2.2 Expiratory resistance
G.2.3 Inspiratory resistance
Annex H (normative) Method of test for apparatus deadspace (backward leak)
H.1 Apparatus
H.2 Procedure
20 Annex I (normative) Method of test for flow through patient demand valves
I.1 Apparatus
I.2 Procedure for initiation of flow
I.3 Procedure for high inspiratory flow
I.4 Procedure for termination of flow
21 Figure I.1 – Apparatus for test for initiation of flow of patient demand valves
Annex J (normative) Method of test for storage and operating conditions
J.1 Apparatus
J.2 Procedure
22 Annex K (informative) Construction and testing of test lungs
BS 6850:2002