BS EN 1253-6:2022
$142.49
Gullies for buildings – Trapped floor gullies with a depth of water seal less than 50 mm
Published By | Publication Date | Number of Pages |
BSI | 2022 | 32 |
This document classifies floor gullies for domestic waste water for use inside buildings, gives guidance for places of installation and specifies requirements for the construction, design, performance and marking of factory made gullies for buildings, irrespective of the material, for use in drainage systems requiring a trap with a depth of water seal less than 50 mm (referred to as floor gullies). NOTE Floor gullies with a depth of water seal less than 50 mm are not covered by EN 1253 1, EN 1253 7 and EN 1253 8. These products are intended to be installed where the three following conditions are met: – space limitation will not accommodate a gully with a 50 mm water seal; – the building does not exceed a ground-floor and three floors above; – at least two domestic sanitary appliances are installed in addition to the gully but with only one WC on the same branch (connection pipe) or secondary or branch ventilation is installed (see EN 12056 2:2000, 4.3.2 or 4.3.4.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
5 | European foreword |
6 | 1 Scope 2 Normative references 3 Terms and definitions |
10 | 4 Design and construction 4.1 General 4.2 Appearance 4.3 Aperture in gratings |
11 | 4.4 Resistance of trap in mechanical closure to pressure 4.4.1 Requirements 4.4.2 Test method |
12 | 4.5 Blockage prevention 4.5.1 Access for cleaning |
13 | 4.5.2 Self-cleansing capacity |
14 | 4.5.3 Anti-blockage 4.6 Places of installation 4.7 Materials |
15 | 4.8 Thermal behaviour of floor gullies 4.8.1 General 4.8.2 Requirements 4.8.3 Test method 4.8.4 Additional test for floor gullies for use with sheet floor coverings and liquid applied membranes |
16 | 4.9 Tightness 4.9.1 Odour-tightness |
18 | 4.9.2 Watertightness of bodies 4.9.3 Watertightness of extensions 4.10 Mechanical strength 4.10.1 Loading strength |
20 | 4.10.2 Clamping ring strength |
21 | 4.10.3 Additional mechanical strength according to the installation |
24 | 4.10.4 Floor gullies for use with liquid applied membranes 4.11 Flow rates 4.11.1 Requirements |
25 | 4.11.2 Test method 4.11.3 Test arrangement |
26 | 5 Allocation and sequence of tests |
27 | 6 Marking |
28 | 7 Evaluation of conformity |
29 | Annex A (normative) Examples of top view of the positioning of shape of test blocks applied on the gratings |
31 | Bibliography |