BS EN 13200-3:2018
$142.49
Spectator facilities – Separating elements. Requirements
Published By | Publication Date | Number of Pages |
BSI | 2018 | 32 |
This document specifies design requirements for layout and product characteristics for separating elements within spectator accommodation at permanent or temporary entertainment venues including sport stadia, sport halls, indoor and outdoor facilities for the purpose of enabling their functionality. Other permanent venues such as theatres, cinemas, opera houses, lecture halls and similar are excluded from this document. Elements and barriers included in this document are: – barrier front of a row of fixed seats; – barrier adjacent to end row of seats; – barrier behind a rear row of seats; – barrier at the foot of a gangway or on stairway, aligned at right angles to the direction of movement; – side or lateral barrier, aligned parallel to the direction of spectator movement; – gangway barriers; – gangway barriers in standing areas, aligned at right angles to the direction of spectator movement; – crush barriers; – barriers for spectator galleries; – external perimeter barriers and barriers between sectors.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
8 | 1 Scope 2 Normative references 3 Terms and definitions |
10 | 4 General requirements 4.1 Preliminary considerations 4.2 Design procedures 4.3 Barrier design and loading 4.4 Barrier heights |
11 | 4.5 Deflection 4.6 Fixings 4.7 Safety details 4.8 Support from adjacent construction 4.9 Maintenance 4.10 Barriers and sightline considerations |
12 | 5 Specific requirements 5.1 General 5.2 External perimeter barriers 5.3 Activity area barriers 5.3.1 Form, height and imposed load 5.3.2 Emergency access to the activity area 5.3.3 Requirements dependent upon sports or activities |
13 | 5.4 Segregation elements |
14 | 5.5 Crush barriers 5.5.1 Main design criteria 5.5.2 Crush barriers – factors determining the horizontal imposed load |
15 | 5.6 Barriers in spectator galleries 5.7 Exit doors and gates 5.7.1 General 5.7.2 Loads 5.8 Temporary barriers |
16 | 5.9 Front of stage barriers |
17 | Annex A (normative)Horizontal imposed loads for barriers in seating accommodation A.1 Table and figures |
22 | A.2 Notes to Annex A |
23 | A.3 Notes to Table A.1 |
24 | Annex B (informative)Horizontal imposed loads for barriers in standing accommodation B.1 Table and figures |
25 | B.2 Notes to Annex B |
26 | Annex C (informative)Horizontal imposed loads for external perimeter barrier and segregation elements C.1 Table and figures |
28 | C.2 Notes to Annex C |
29 | Annex D (informative)Breaking of load related to grade slope |