Fire classification of construction products and building elements – Classification using data from external fire exposure to roofs tests

Published By Publication Date Number of Pages
BSI 2016 34
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This European Standard provides the fire performance classification procedures for roofs/roof coverings exposed to external fire based on the four test methods given in CEN/TS 1187:2012 and the relevant extended application rules.

For the classification of a roof/roof covering, only those test methods and those application rules need to be applied for which the corresponding classification is envisaged.

Products are considered in relation to their end use application.

NOTE

The distinction between roofs with a steep slope and facades, in terms of the test and classification standard to be applied, may be subject to national regulations.

General information on the four test methods in CEN/TS 1187 is given in Annex A.

PDF Catalog

PDF Pages PDF Title
4 Contents Page
8 1 Scope
2 Normative references
3 Terms and definitions
9 4 Classes of external fire performance of roofs/roof coverings
5 Test methods
5.1 General
10 5.2 Test 1: Method with burning brands
5.3 Test 2: Method with burning brands and wind
5.4 Test 3: Method with burning brands, wind and supplementary radiant heat
5.5 Test 4: Two-stage method incorporating burning brands, wind and supplementary radiant heat
6 Principles for specimen preparation, testing and classification
6.1 General requirements for specimen preparation
11 6.2 General requirements for testing
6.3 Selection of test methods
6.4 Field of application
12 6.5 Specific requirements
6.5.1 General
6.5.2 Test 1
6.5.2.1 General
6.5.2.2 Pitch
6.5.2.3 Nature of the deck
6.5.2.4 Positioning of joints
13 6.5.2.5 Direct field of application of test results
6.5.2.6 Field of extended application
14 6.5.3 Test 2
6.5.3.1 General
6.5.3.2 Pitch
6.5.3.3 Nature and selection of the substrate
6.5.3.4 Direct field of application of test results
6.5.3.5 Field of extended application
15 6.5.4 Test 3
6.5.4.1 General
6.5.4.2 Pitch
6.5.4.3 Nature of the deck
6.5.4.4 Direct field of application of test result
16 6.5.4.5 Test with alternative supporting deck
6.5.4.6 Field of extended application
6.5.5 Test 4
6.5.5.1 General
6.5.5.2 Pitch
6.5.5.3 Nature of deck
17 6.5.5.4 Inclusion of joints
6.5.5.5 Direct field of application of test results
6.5.5.6 Field of extended application
7 Number of tests for classification
8 Classification parameters
8.1 General
8.2 Test 1
18 8.3 Test 2
8.4 Test 3
8.5 Test 4
9 Classes and criteria
20 10 Classification report
10.1 General
10.2 Content and format
22 Annex A (informative)General information on the four test methods in CEN/TS 1187
23 Annex B (normative)Classification report for roofs/roof coverings exposed to external fire
B.1 General layout
B.2 Introduction
B.3 Description of the roof/roof covering
24 B.4 Reports and results in support of this classification
B.4.1 Reports
B.4.2 Test results
B.4.2.1 Test 1
25 B.4.2.2 Test 2
B.4.2.3 Test 3
26 B.4.2.4 Test 4
27 B.5 Classification and field of application
B.5.1 Reference
B.5.2 Classification
B.5.3 Field of application
B.6 Limitations
B.6.1 Restrictions
B.6.2 Warning
BS EN 13501-5:2016