Thermal insulation products for building equipment and industrial installations. Factory made calcium silicate (CS) products. Specification

Published By Publication Date Number of Pages
BSI 2015 40
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This European Standard specifies the requirements for factory made calcium silicate products which are used for the thermal insulation of building equipment and industrial installations with an operating temperature range of approximately – 170 °C to + 1 100 °C.

NOTE Calcium silicate products can be used below – 50 °C. Below the operating temperature of – 50 °C, special tests, regarding the suitability of the product in the intended application are advised (e.g. liquefaction of oxygen). Manufacturer’s advice should be heeded in all cases.

The products are manufactured in the form of boards, pipe sections, segments and prefabricated ware.

This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.

Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the structural performance of systems incorporating these products is not covered.

This standard does not specify the required level or class of a given property that shall be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application can be found in regulations and invitations to tender.

Products with a declared thermal conductivity greater than 0,6 W/(mK) at 10 °C are not covered by this standard.

This standard does not cover products intended to be used for the insulation of the building structure.

This standard does not cover the following acoustical aspects: direct airborne sound insulation and impact noise transmission index.

PDF Catalog

PDF Pages PDF Title
4 Contents Page
5 Foreword
7 1 Scope
2 Normative references
8 3 Terms, definitions, symbols, units and abbreviated terms
3.1 Terms and definitions
9 3.1.1 Terms and definitions as given in EN ISO 9229:2007
3.1.2 Additional terms and definitions
3.2 Symbols, units and abbreviated terms
3.2.1 Symbols and units used in this standard
10 3.2.2 Abbreviations used in this standard
11 4 Requirements
4.1 General
4.2 For all applications
4.2.1 Thermal conductivity
4.2.2 Dimensions and tolerances
4.2.2.1 Linear dimensions
12 4.2.2.2 Squareness
4.2.2.3 Flatness
4.2.2.4 Pipe section linearity
4.2.3 Dimensional stability
4.2.4 Reaction to fire of the product as placed on the market
13 4.2.5 Durability characteristics
4.2.5.1 General
4.2.5.2 Durability of reaction to fire against ageing/degradation and high temperature
4.2.5.3 Durability of thermal resistance against ageing/degradation
4.2.5.4 Durability of thermal resistance against high temperature
4.3 For specific applications
4.3.1 General
4.3.2 Maximum service temperature
14 4.3.3 Minimum service temperature
4.3.4 Compressive stress or compressive strength
15 4.3.5 Trace quantities of water soluble ions and the pH-value
4.3.6 Water vapour diffusion resistance
4.3.7 Short term water absorption by partial immersion
4.3.8 Release of dangerous substances
4.3.9 Continuous glowing combustion
5 Test methods
5.1 Sampling
5.2 Conditioning
16 5.3 Testing
5.3.1 General
17 5.3.2 Thermal conductivity
18 5.3.3 Maximum service temperature
5.3.3.1 Test specimens
5.3.4 Reaction to fire
6 Designation code
7 Evaluation of conformity
7.1 General
19 7.2 Initial Type Testing
7.3 Factory Production Control
8 Marking and labelling
20 Annex A (normative) Factory production control
23 Annex B (normative) Determination of minimum service temperature
B.1 Definitions
B.2 Principle
B.3 Apparatus
B.3.1 Guarded hot plate apparatus, to measure the thermal conductivity
B.3.2 Hot wire apparatus, to measure the thermal conductivity
24 B.3.3 Micrometer
B.3.4 Sliding caliper
B.4 Test specimens
B.4.1 Dimensions of test specimens
B.4.2 Number of test specimens
B.4.3 Conditioning of the test specimens
B.5 Procedure
B.5.1 Test conditions
B.5.2 Test procedure
25 B.5.3 Alternative test procedure
B.6 Calculation and expression of results
B.6.1 Dimensional changes
26 B.6.2 Additional tests and/or observation
B.7 Accuracy of measurements
B.8 Test report
27 Annex C (informative) Preparation of the test specimens to measure thermal conductivity
C.1 Preparation of the test specimens to measure thermal conductivity
C.2 Ageing
28 Annex D (informative) Additional properties
D.1 General
D.2 Coefficient of thermal expansion
D.3 Apparent and true porosity
D.4 Air flow resistance
D.5 Creep in compression
D.6 Permeability to gases
D.7 Acoustic properties
D.8 Bending strength
29 D.9 Apparent density
30 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Directive
ZA.1 Scope and relevant characteristics
32 ZA.2 Procedures for attestation of conformity of factory made calcium silicate products
ZA.2.1 Systems of attestation of conformity
34 ZA.2.2 EC certificate and declaration of conformity
36 ZA.3 CE Marking and labelling
38 Bibliography
BS EN 14306:2009+A1:2013
$167.15