Shopping Cart

No products in the cart.

BS EN 15193-1:2017+A1:2021

$215.11

Energy performance of buildings. Energy requirements for lighting – Specifications, Module M9

Published By Publication Date Number of Pages
BSI 2021 110
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This standard specifies the methodology for evaluating the energy performance of lighting systems for providing general illumination in residential and non-residential buildings and for calculating or measuring the amount of energy required or used for lighting in buildings. The method may be applied to new, existing or refurbished buildings. It also provides a methodology (LENI) as the measure of the energy efficiency of the lighting installations in buildings.

This standard does not cover lighting requirements, the design of lighting systems, the planning of lighting installations, the characteristics of lighting equipment (lamps, control gear and luminaires) and systems used for display lighting, desk lighting or luminaires built into furniture. This standard does not provide any procedure for the dynamic simulation of lighting scene setting.

Table 1 shows the relative position of this standard within the set of EPB standards in the context of the modular structure as set out in EN ISO 52000?1 .

NOTE

In CEN ISO/TR 52000?2 the same table can be found, with, for each module, the numbers of the relevant EPB standards and accompanying technical reports that are published or in preparation.

The modules represent EPB standards, although one EPB standard may cover more than one module and one module may be covered by more than one EPB standard, for instance a simplified and a detailed method respectively. See also Clause 2.

Table 1
Position of this standard within the modular structure of the set of EPB standards
a

The shaded modules are not applicable.

PDF Catalog

PDF Pages PDF Title
2 undefined
11 1 Scope
13 2 Normative references
3 Terms and definitions
14 4 Symbols and abbreviations
20 5 Brief description of the method(s) and routing
22 6 Method 1 – Calculation of the energy required for lighting
32 7 Method 2 – Quick calculation of the energy required for lighting
36 8 Method 3 – Metered energy used for lighting
38 9 Quality control
10 Compliance check
40 Annex A (normative)Input and method selection data sheet — Template
A.1 General
A.2 System design data
A.2.1 General
41 A.2.2 Standby energy density
A.2.3 Annual operating hours
A.2.4 Daylight supply factor for vertical façades
A.2.5 Daylight supply factor for roof lights
A.2.6 Absence factor (FA) for rooms in building types
42 A.2.7 Example constant illuminance dependency factors (FC)
A.2.8 Installed power for residential buildings
43 A.2.9 Useful areas in residential buildings
44 Annex B (informative)Input and method selection data sheet — Default choices
B.1 General
B.2 Method 1
B.2.1 Luminaire description data
B.2.2 Luminaire technical data tables
45 B.2.3 System design data
B.3 Method 2
B.3.1 Luminaire description data
B.3.2 Luminaire technical data tables
B.3.3 System design data
B.3.3.1 General
B.3.3.2 Standby energy density
B.3.3.3 Annual operating hours
46 B.3.3.4 Daylight supply factor for vertical façades
B.3.3.5 Daylight supply factor for roof lights
B.3.3.6 Absence factor (FA) for rooms in building types
49 B.3.3.7 Example constant illuminance dependency factors (FC)
50 B.3.3.8 Installed power for residential buildings
51 B.3.3.9 Useful areas in residential buildings
B.4 Method 3
52 Annex C (normative)Simplified Method for Installed Power Estimation
C.1 General
C.2 Installed power assessment for non-residential buildings
54 C.3 Installed power assessment for residential buildings
55 Annex D (normative)Assessment of the installed power for lighting systems in existing buildings
56 Annex E (normative)Occupancy estimation
61 Annex F (normative)Daylight availability
F.1 General
63 F.2 Building segmentation: Spaces benefiting from daylight
65 F.3 Daylight supply factor for vertical façades
F.3.1 Daylight factor classification
71 F.3.2 Daylight supply factor
F.3.2.1 General
72 F.3.2.2 Luminous exposure at different sites (climates and latitudes)
F.3.2.3 Relative times, shading activated, shading not activated for vertical façades
74 F.3.2.4 Determination of daylight supply factor for sun shading not activated FD,S,SNA,j
81 F.3.2.5 Determination of daylight supply factor for sun shading activated FD,S,SA,j
83 F.4 Daylight supply factor for roof lights
F.4.1 General
F.4.2 Daylight availability factor
88 F.4.3 Daylight supply factor
89 F.4.4 Relative times, shading activated/ not activated for roof lights
91 F.4.5 Daylight supply factors as function of the daylight availability classification
95 F.5 !Daylight supply factor for windows in sloped roofs
97 F.6 Daylight Responsive Control Systems
99 F.7 Monthly evaluation method
100 F.8 Determination of daytime and night time hours
103 F.9 Comprehensive calculation
104 F.10 Collection of input data required for daylight calculations
105 Annex G (normative)Constant illuminance
G.1 General
G.2 Constant illuminance factor (Fc)
106 G.3 Constant lumen output system (CLO)
107 Annex H (normative)Standby system energy requirements
H.1 Emergency lighting luminaire standby charging power (Pem)
H.2 Lighting controls standby power (Ppc)
BS EN 15193-1:2017+A1:2021
$215.11