Shopping Cart

No products in the cart.

BS EN 50281-1-1:1999:2002 Edition

$142.49

Electrical apparatus for use in the presence of combustible dust. Electrical apparatus protected by enclosures – Construction and testing

Published By Publication Date Number of Pages
BSI 2002 26
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Specifies requirements for design, construction and testing based on limitation of maximum surface temperature, restriction of dust ingress and use of dust-tight or dust protected enclosures.

PDF Catalog

PDF Pages PDF Title
1 BRITISH STANDARD
2 National foreword
4 Foreword
Foreword to amendment A1
Contents
5 Introduction
1 Scope
6 2 Normative references
7 3 Definitions
3.1 dust
3.2 combustible dust
3.3 conductive dust
3.4 explosive dust atmosphere
3.5 ignition temperature of a dust layer
3.6 ignition temperature of a dust cloud
3.7 dust ignition protection
3.8 dust-tight enclosure
3.9 dust-protected enclosure
3.10 maximum surface temperature
3.11 maximum permissible surface temperature
8 3.12 equipment group II category 1
3.13 equipment group II category 2
3.14 equipment group II category 3
4 Requirements for all category 1 and 2 electrical apparatus
4.1 General
9 4.2 Non metallic enclosures and non metallic parts of enclosures
10 4.3 Fasteners
4.4 Interlocking devices
4.5 Bushings in enclosures
4.6 Materials used for cementing
11 4.7 Connection facilities and terminal compartments
4.8 Connection facilities for earthing and bonding conductors
Table 1 – Minimum cross-sectional areas of protective conductors
4.9 Cable and conduit entries
12 4.10 Radiating equipment
5 Supplementary requirements for certain category�2�electrical apparatus
5.1 Rotating electrical machines
13 5.2 Switchgear
14 5.3 Fuses
5.4 Plugs and sockets
5.5 Luminaires
15 5.6 Caplights, caplamps and handlamps
6 Requirements for all category 3 electrical apparatus
6.1 General
6.2 Non-metallic enclosures and non-metallic parts of enclosures
16 6.3 Fasteners
6.4 Interlocking devices
6.5 Bushings in enclosures
6.6 Materials used for cementing
6.7 Connection facilities and terminal compartments
6.8 Connection facilities for earthing and bonding conductors
17 Table 2 – Minimum cross-sectional areas of protective conductors
6.9 Cable and conduit entries
6.10 Radiating equipment
18 7 Supplementary requirements for certain category�3 electrical apparatus
7.1 Rotating electrical machines
7.2 Switchgear
7.3 Fuses
7.4 Plugs and sockets
19 7.5 Luminaires
7.6 Caplights, caplamps and handlamps
20 8 Type verification and tests
9 Dust tightness test
9.1 Dust tight apparatus
9.2 Dust protected apparatus
10 Thermal tests for category 1, 2 and 3 electrical apparatus
10.1 Temperature measurement
21 10.2 Temperature control
10.3 Ambient temperature range
22 10.4 Maximum surface temperature of the enclosure�T
10.5 Category 1 apparatus
11 Marking
11.1 The electrical apparatus shall be marked on the main part in a visible place. This marking s…
11.2 The marking shall include:
11.3 Supplementary marking of apparatus
23 12 Examples of marking
12.1 Marking for category 1 or 2 apparatus
12.2 Marking for category 3 apparatus
24 13 Instructions
BS EN 50281-1-1:1999