Shopping Cart

No products in the cart.

BS EN 50281-1-2:1999:2002 Edition

$102.76

Electrical apparatus for use in the presence of combustible dust. Electrical apparatus protected by enclosures – Selection, installation and maintenance

Published By Publication Date Number of Pages
BSI 2002 16
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Gives guidance on selection, installation and maintenance of electrical apparatus to be constructed in accordance with BS EN 50281-1-1.

PDF Catalog

PDF Pages PDF Title
1 BRITISH STANDARD
2 National foreword
4 Foreword
Foreword to amendment A1
Contents
5 Introduction
1 Scope
6 2 Normative references
3 Definitions
3.1 dust
3.2 combustible dust
3.3 conductive dust
3.4 explosive dust atmosphere
3.5 ignition temperature of a dust layer
3.6 ignition temperature of a dust cloud
3.7 dust ignition protection
7 3.8 dust-tight enclosure
3.9 dust-protected enclosure
3.10 maximum surface temperature
3.11 maximum permissible surface temperature
4 Area classification
4.1 Zone 20
4.2 Zone 21
4.3 Zone 22
8 5 Selection of apparatus
6 Temperature limitation
6.1 Temperature limitations because of the presence of dust clouds
6.2 Temperature limitation because of the presence of dust layers
9 Figure 1 – Reduction in maximum permissible surface temperature for increasing depth of dust layers
6.3 Apparatus to be submitted to laboratory investigation
10 6.4 Maximum permissible surface temperature
7 Selection of dust ignition protected apparatus
8 Selection of radiating equipment
8.1 Ignition process
11 8.2 Safety measures in all Zones
9 Selection of ultrasonic equipment
9.1 Ignition process
9.2 Safety measures
10 Installation requirements
10.1 General
10.2 Access for inspection
12 10.3 Plans and records
10.4 Installation of apparatus
10.5 Integrity of insulation
10.6 Isolation
11 Wiring systems
11.1 Types of wiring
11.2 Electrostatic build�up of charges
11.3 Dust collection
11.4 Entries
13 11.5 Accessories
11.6 Course of wiring
11.7 Thermal rating
11.8 Barriers
11.9 Flexible connection
11.10 Metal conduit systems
11.11 Plastic conduit systems
11.12 Conduit system joints
14 12 Inspection and maintenance
12.1 Qualifications of personnel
12.2 Isolation
12.3 Maintenance
12.4 Examination
15 Annex A (informative) Examples for dust layers with excessive thickness with the requirement of laborator…
BS EN 50281-1-2:1999