Shopping Cart

No products in the cart.

BS EN 50367:2020+A1:2022

$215.11

Railway applications. Fixed installations and rolling stock. Criteria to achieve technical compatibility between pantographs and overhead contact line

Published By Publication Date Number of Pages
BSI 2022 80
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
2 undefined
11 Blank Page
12 1 Scope
2 Normative references
13 3 Terms and definitions
16 4 Symbols and abbreviations
19 5 Geometry
5.1 General
5.2 Overhead contact line characteristics
5.2.1 General
5.2.2 Infrastructure gauge for free passage of pantograph
20 5.2.3 Contact wire height
5.2.4 Contact wire gradient
5.2.5 Lateral deviation of contact wire
5.2.5.1 General
21 5.2.5.2 Limit of dewirement – limit of stability for lateral interaction
23 5.2.5.3 Serviceability limit state
5.2.6 Contact wire uplift
5.2.7 Neutral sections
24 5.2.8 Change over area between pantograph profiles
5.3 Pantograph characteristics
5.3.1 General
25 5.3.2 Assessment of the pantograph head profile
5.3.2.1 General
5.3.2.2 Continuous pantograph head profile (non-independently suspended contact strips)
26 5.3.2.3 Non-continuous pantograph head profile (independently suspended collector strips)
28 5.3.3 Conducting range
6 Interface material
6.1 General
29 6.2 Contact wire
6.3 Contact strips
7 Interaction performance
7.1 General
7.2 Static contact forces and current capacity
30 7.3 Dynamic behaviour and quality of current collection
33 8 Operational requirements
8.1 Requirement for pantograph
8.2 Minimum and maximum distance between two operating pantographs
8.2.1 General
8.2.2 Design of overhead contact lines
34 Blank Page
35 9.2 Overhead contact line
9.2.1 Assessment of overhead contact line design
9.2.1.1 Simulation
9.2.1.2 Measurement
9.2.2 Integration of an assessed OCL into a network
36 9.3 Pantograph
9.3.1 Assessment of pantograph design
9.3.1.1 Simulation
9.3.1.2 Measurement
9.3.2 Integration of an assessed pantograph into a vehicle
38 Annex A (normative)Special requirements
A.1 Neutral sections
A.1.1 Principle of neutral section
A.1.2 Long neutral section
39 A.1.3 Short neutral section
A.1.4 Split neutral section
40 A.1.5 Arrangement of pantographs on trains
41 A.2 Profiles for interoperable pantograph head
A.2.1 Pantograph head with length of 1 600 mm
42 A.2.2 Pantograph head with length of 1 950 mm
A.3 Additional tests for DC systems at standstill
A.3.1 General
43 A.3.2 Testing conditions
A.3.2.1 Conditions for the contact wire(s)
A.3.2.2 Conditions for the contact strip(s)
A.3.2.3 Environmental conditions
A.3.3 Testing method
A.3.3.1 Complete pantograph configuration
45 A.3.4 Test results
46 A.4 Visualization of mean contact forces
48 Annex B (informative)Data of existing networks
B.1 General
B.2 National characteristics
54 B.3 General characteristics of pantograph head
61 Annex C (normative)Additional tests for DC at standstill – alternative method – Test method – Single strip configuration
62 Annex D (informative)Specimen calculation for the permissible lateral deviation of the contact wire according to the requirements of 5.2.5 with typical values from the German network
D.1 Calculation Values
64 D.2 Calculation independent of type of pantograph
D.2.1 Calculation of reference height
D.2.2 Calculation of tolerances of track at the lower verification point
D.2.3 Calculation of tolerances of track at the upper verification point
D.2.4 Calculation of additional overthrow on the inside/outside of the curve for pantographs
65 D.2.5 Calculation of quasi static effect
D.3 Pantograph head with length of 1600 mm
D.3.1 Calculation of lateral movement of contact wire caused by forces from non-horizontal sections of pantograph head
D.3.2 Calculation of tolerances of overhead contact line
D.3.3 Calculation of width of mechanical kinematic pantograph gauge at minimum verification height of the pantograph gauge in a raised position
66 D.3.4 Calculation of width of mechanical kinematic pantograph gauge at maximum verification height of the pantograph gauge in a raised position
D.3.5 Calculation of width of mechanical kinematic pantograph gauge at reference height for interaction between contact wire and pantograph
D.3.6 permissible lateral deviation of the contact wire for stability against dewirement according to 5.2.5.2
67 D.3.7 Calculation of width of mechanical kinematic gauge for serviceability of overhead contact line at minimum verification height of the pantograph gauge in a raised position
D.3.8 Calculation of width of mechanical kinematic gauge for serviceability of overhead contact line at maximum verification height of the pantograph gauge in a raised position
D.3.9 Calculation of width of mechanical gauge for serviceability of overhead contact line gauge at reference height for interaction between contact wire and pantograph
68 D.3.10 Permissible lateral deviation of the contact wire from the track centre line to meet the serviceability limit state case according to 5.2.5.3
D.3.11 Permissible lateral deviation of the contact wire from the track centre line according to 5.2.5.3
69 D.4 Pantograph head with length of 1 950 mm
D.4.1 Calculation of lateral movement of contact wire caused by forces from non-horizontal sections of pantograph head
D.4.2 Calculation of tolerances of overhead contact line
D.4.3 Calculation of width of mechanical kinematic pantograph gauge at minimum verification height of the pantograph gauge in a raised position
D.4.4 Calculation of width of mechanical kinematic pantograph gauge at maximum verification height of the pantograph gauge in a raised position
70 D.4.5 Calculation of width of mechanical kinematic pantograph gauge at reference height for interaction between contact wire and pantograph
D.4.6 permissible lateral deviation of the contact wire for stability against dewirement according to 5.2.5.2
D.4.7 Calculation of width of mechanical kinematic gauge for serviceability of overhead contact line at minimum verification height of the pantograph gauge in a raised position
71 D.4.8 Calculation of width of mechanical kinematic gauge for serviceability of overhead contact line at maximum verification height of the pantograph gauge in a raised position
D.4.9 Calculation of width of mechanical gauge for serviceability of overhead contact line gauge at reference height for interaction between contact wire and pantograph
D.4.10 Permissible lateral deviation of the contact wire from the track centre line to meet the serviceability limit state case according to 5.2.5.3
72 D.4.11 Permissible lateral deviation of the contact wire from the track centre line according to 5.2.5.3
73 D.5 Illustration lateral deviation
77 Annex ZA (informative)Relationship between this European standard and the essential requirements of EU Directive 2016/797/EU [2016 OJ L138] aimed to be covered
BS EN 50367:2020+A1:2022
$215.11