Shopping Cart

No products in the cart.

BS EN 50577:2015

$142.49

Electric cables. Fire resistance test for unprotected electric cables (P classification)

Published By Publication Date Number of Pages
BSI 2015 32
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This European Standard specifies a test method to evaluate the maintenance of circuit integrity of electric cables which have intrinsic resistance to fire under fire conditions, in order to classify the electric cable according to EN 13501‑3 .

The test determines the survival time for circuit integrity of the electric cable when exposed to fire under the conditions of the EN 1363‑1 standard time/temperature curve.

This European Standard is used in conjunction with EN 1363‑1 .

This European Standard applies to electric power and control cables with rated voltage up to and including 600/1 000 V.

The cable is tested in a standardized representative installation condition.

The test does not assess the performance of the cable management system.

NOTE

Optical fibre cables and copper communication cables could be tested using this test method, however verification procedures for such cables were still under development when this document has been circulated for vote (2015-07-24).

This European Standard includes field of direct application ( Annex A) and rules for extended application of test results (EXAP) ( Annex B).

The selection of cables to be tested for classification of a family is given in Annex B. In case the selection of the cables does not comply with Annex B, the test results are only applicable to the tested cables.

PDF Catalog

PDF Pages PDF Title
6 European foreword
7 Introduction
8 1 Scope
2 Normative references
9 3 Terms and definitions
4 Test equipment
4.1 Test furnace
4.2 Continuity and voltage withstand checking arrangement (See Figure 15)
10 4.3 Fuse
4.4 Standardized representative installation
4.4.1 General
4.4.2 System components
4.4.2.1 Cable tray
4.4.2.2 Suspensions and horizontal supports (U-shaped and perforated)
4.4.2.3 90-degree fittings
11 4.4.2.4 Right-angled brackets
4.4.3 Loading
4.4.4 General arrangements of installation in furnace
13 4.5 Installation of standardized representative installation
4.5.1 Details of “U” bend arrangement
15 4.5.2 Details of “S” bend arrangement
16 4.5.3 Application of the chains
4.5.4 Exit holes from the furnace for the test installation
18 5 Test conditions
5.1 Environmental conditions
5.2 Furnace control
6 Test specimen
6.1 Length of test specimen
19 6.2 Number of test specimens
6.3 Conditioning
6.4 Specimen preparation
6.5 Mounting of test specimens
20 7 Test procedure
7.1 General
7.2 Measuring temperature
22 7.3 Applying the voltage
23 7.4 Starting the test
8 Duration of survival
8.1 Point of failure
24 8.2 Survival time
9 Test report
25 Annex A (normative) Field of direct application
A.1 Terms and definitions
A.2 Cable Management System
A.3 Orientation
A.4 Bending radius
26 Annex B (normative) Extended application of test results
B.1 General
B.2 Terms and definitions
B.3 Product families for EXAP
27 B.4 EXAP procedure
29 Bibliography
BS EN 50577:2015
$142.49