BS EN 60079-6:2015 – TC:2020 Edition
$186.33
Tracked Changes. Explosive atmospheres – Equipment protection by liquid immersion “o”
Published By | Publication Date | Number of Pages |
BSI | 2020 | 73 |
IEC 60079-6:2015 specifies the requirements for the design, construction, testing and marking of Ex Equipment and Ex Components with type of protection liquid immersion ‘o’ intended for use in explosive gas atmospheres. Ex Equipment and Ex Components of type of protection liquid immersion ‘o’ are either: – Level of Protection ‘ob’ (EPL ‘Mb’ or ‘Gb’) or – Level of Protection ‘oc’ (EPL ‘Gc’). For Level of Protection ‘ob’, this standard applies where the rated voltage does not exceed 11 kV r.m.s. a.c. or d.c. For Level of Protection ‘oc’, this standard applies where the rated voltage does not exceed 15 kV r.m.s. a.c. or d.c. This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence. This fourth edition cancels and replaces the third edition, published in 2007. This edition constitutes a technical revision. The significant changes with respect to the previous edition are: – Edition 4 represents a major technical revision of the requirements for oil immersion ‘o’ and should be considered as introducing all new requirements. The normal ‘Table of Significant Changes’ has not been included for this reason. In particular: – The requirements for oil immersion ‘o’ have been redefined into liquid immersion, levels of protection ‘ob’ and ‘oc’ as recommended by the responses to 31/715/DC; – The ability to protect sparking contacts has been added to both ‘ob’ and ‘oc’. Additional requirements have been introduced for the protective liquid. Keywords: Ex Equipment and Ex Components with type of protection liquid immersion ‘o’
PDF Catalog
PDF Pages | PDF Title |
---|---|
52 | English CONTENTS |
54 | FOREWORD |
56 | 1 Scope 2 Normative references |
57 | 3 Terms and definitions |
58 | 4 Constructional requirements 4.1 General 4.2 Levels of protection and requirements of electrical equipment 4.2.1 Level of Protection |
59 | 4.2.2 Requirements for Level of Protection “ob” 4.2.3 Requirements for Level of Protection “oc” 4.3 Switching device 4.4 Creepage and clearance Table 1 – Working voltage |
60 | 4.5 Liquid containment enclosures 4.5.1 General 4.5.2 Sealed enclosures 4.5.3 Unsealed enclosures 4.5.4 Outlet of breathing device or pressure relief device 4.5.5 Enclosures intended to be opened 4.5.6 Determination of the maximum/minimum criteria of the protective liquid |
61 | 4.6 Immersion depth 4.7 Protective liquid level indication 4.7.1 General Table 2 – Depth of immersion |
62 | 4.7.2 Remote-indicating protective liquid level indicator 4.7.3 Safety devices for Level of Protection “ob” 4.8 Temperature limitations 4.8.1 General 4.8.2 Maximum Surface Temperature 4.8.3 Flashpoint of the protective liquid 4.9 Field wiring connections to liquid immersion equipment 4.10 Constructional elements of enclosures 4.10.1 Operating rods, shafts etc. |
63 | 4.10.2 Devices for draining of liquid 5 Protective Liquid 5.1 Protective liquid specification 5.2 Detailed alternative specification 5.3 Group I equipment 5.4 Liquid contamination and gassing that may result from arcing |
64 | 5.5 Total volume of the protective liquid 6 Verifications and tests 6.1 Type tests 6.1.1 Overpressure test on sealed enclosures 6.1.2 Reduced pressure test on sealed enclosures 6.1.3 Overpressure test on unsealed enclosures 6.1.4 Maximum temperature |
65 | 6.1.5 Switching Tests 6.2 Routine tests 6.2.1 Sealed enclosures 6.2.2 Unsealed enclosures 7 Marking |
66 | 8 Instructions |
67 | Annex A (normative) Selection and erection requirements |
68 | Annex B (normative) Maintenance requirements Table B.1 – Inspection requirements |
69 | Annex C (normative) Repair and Overhaul requirements |
70 | Bibliography |