BS EN 60432-3:2013
$167.15
Incandescent lamps. Safety specifications – Tungsten-halogen lamps (non-vehicle)
Published By | Publication Date | Number of Pages |
BSI | 2013 | 36 |
IEC 60432-3:2012 specifies the safety requirements for single-capped and double-capped tungsten halogen lamps, having rated voltages of up to 250 V, used for the following applications: – projection (including cinematograph and still projection), – photographic (including studio), – floodlighting, – special purpose, – general purpose, – stage lighting. This second edition of IEC 60432-3 cancels and replaces the first edition published in 2002, Amendment 1 (2005) and Amendment 2 (2008). The main changes with respect to the previous edition are as follows: – adapting the cold fill pressure requirements and tests for self-shielded lamps to the state of the technology, – introduction of requirements to fully cover photobiological safety according to IEC 62471.
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | English CONTENTS |
8 | 1 General 1.1 Scope 1.2 Normative references |
9 | 1.3 Terms and definitions |
11 | 2 Requirements 2.1 General |
12 | 2.2 Marking 2.2.1 Lamp marking 2.2.2 Additional information and marking |
13 | 2.3 Caps or bases 2.3.1 General 2.3.2 Creepage distances 2.3.3 Dimensions |
14 | 2.4 Photobiological safety 2.5 Gas pressure of low-pressure self-shielded extra low voltage lamps 2.6 Safety at end of life of self-shielded lamps with rated voltages from range B or C 2.7 Information for luminaire design |
15 | 3 Assessment 3.1 General 3.2 Whole production assessment by means of manufacturer’s records |
16 | Tables Table 1 – Grouping of test records – Sampling and acceptable quality levels (AQL) |
17 | Table 2 – Acceptance numbers AQL = 0,25 % Table 3 – Acceptance numbers AQL = 0,65 % |
18 | Table 4 – Acceptance numbers AQL = 2,5 % |
19 | 3.2.1 Assessment of manufacturer’s records for particular tests 3.2.2 Sampling procedures for the whole production testing |
20 | 3.3 Assessment of batches 3.3.1 Sampling for batch testing 3.3.2 Number of lamps in the batch sample 3.3.3 Sequence of the tests 3.3.4 Rejection conditions of batches Table 5 – Batch sample size and rejection number |
21 | Annex A (normative) Symbols |
23 | Annex B (normative) Method of testing the gas-pressure |
24 | Annex C (informative) Information for luminaire design |
25 | Table C.1 – Fuse values for general purpose ELV tungsten halogen lamps |
26 | Table C.2 – Fuse values for photographic lamps Table C.3 – List of maximum bulb temperatures |
27 | Table C.4 – Maximum base-pin temperatures |
28 | Table C.5 – Maximum contact temperatures Table C.6 – Maximum reflector-rim temperatures |
30 | Annex D (normative) Conditions of compliance for design tests |
31 | Annex E (informative) Bulb wall temperature measurement |
32 | Annex F (normative) Induced failure test |
34 | Bibliography |