Shopping Cart

No products in the cart.

BS EN 60679-6:2011

$142.49

Quartz crystal controlled oscillators of assessed quality – Phase jitter measurement method for quartz crystal oscillators and SAW oscillators. Application guidelines

Published By Publication Date Number of Pages
BSI 2011 26
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of the IEC 60679 series applies to the phase jitter measurement of quartz crystal oscillators and SAW oscillators used for electronic devices and gives guidance for phase jitter that allows the accurate measurement of r.m.s. jitter.

In the measurement method, phase noise measurement equipment or a phase noise measurement system is used.

The measuring frequency range is from 10 MHz to1 000 MHz.

This standard applies to quartz crystal oscillators and SAW oscillators used in electronic devices and modules that have the multiplication or division functions based on these oscillators. The type of phase jitter applied to these oscillators is the r.m.s. jitter. In the following text, these oscillators and modules will be referred to as “oscillator(s)” for simplicity.

PDF Catalog

PDF Pages PDF Title
6 English

CONTENTS
8 INTRODUCTION
10 1 Scope
2 Normative references
3 Terms, definitions and general concepts
3.1 Terms and definitions
3.2 General concepts
11 Figures

Figure 1 – Voltage versus time
12 Figure 2 – Explanatory diagram of the amount of jitter applied to r.m.s. jitter
13 Figure 3 – Explanatory diagram of random jitter, deterministic jitter, and total jitter
14 3.3 Points to be considered for measurement
15 4 Measurement method
4.1 General
4.2 Frequency range and the measurement method
4.3 Method using the phase noise measurement value
16 4.4 Measurement method using the specially designed measurement equipment
4.5 Block diagram of the measurement
17 4.6 Input and output impedance of the measurement system
4.7 Measurement equipment
Figure 4 – Equivalent block diagram
18 4.8 Test fixture
4.9 Cable, tools and instruments
5 Measurement and the measurement environment
5.1 Set-up before taking measurements
5.2 Points to be considered and noted at the time of measurement
19 5.3 Treatment after the measurement
6 Measurement
6.1 Reference temperature
6.2 Measurement of temperature characteristics
6.3 Measurement under vibration
6.4 Measurement at the time of impact
6.5 Measurement in accelerated ageing
7 Other points to be noted
8 Miscellaneous
20 Annex A (normative)
Calculation method for the amount of phase jitter
21 Figure A.1 – Concept diagram of SSB phase noise
23 Bibliography
BS EN 60679-6:2011
$142.49