BS EN 61249-2-40:2013
$142.49
Materials for printed boards and other interconnecting structures – Reinforced base materials clad and unclad. High performance, non-halogenated epoxide woven E-glass laminate sheets of defined flammability (vertical burning test), copper-clad for lead-free assembly
Published By | Publication Date | Number of Pages |
BSI | 2013 | 28 |
This part of IEC 61249 specifies requirements for properties of modified non-halogenated epoxide woven E-glass laminated sheet of a thickness of 0,05 mm up to 3,2 mm, of defined flammability (vertical burning test), copper-clad. The glass transition temperature is defined to be 170 °C minimum.
Its flame resistance is defined in terms of the flammability requirements of 7.3.
Some property requirements may have several classes of performance. The class desired should be specified on the purchase order, otherwise the default class of material will be supplied.
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | English CONTENTS |
8 | 1 Scope 2 Normative references 3 Materials and construction 3.1 General 3.2 Resin system |
9 | 3.3 Metal foil 3.4 Reinforcement 4 Internal marking 5 Electrical properties Tables Table 1 – Electrical properties |
10 | 6 Non-electrical properties of the copper-clad laminate 6.1 Appearance of the copper-clad sheet 6.1.1 General 6.1.2 Indentations (pits and dents) 6.1.3 Wrinkles 6.1.4 Scratches Table 2 – Indentations |
11 | 6.1.5 Raised areas 6.1.6 Surface waviness 6.2 Appearance of the unclad face 6.3 Laminate thickness Table 3 – Nominal thickness and tolerance of metal-clad laminate |
12 | 6.4 Bow and twist 6.5 Properties related to the copper foil bond Table 4 – Bow and twist requirements Table 5 – Pull-off and peel strength requirements |
13 | 6.6 Punching and machining 6.7 Dimensional stability Table 6 – Dimensional stability |
14 | 6.8 Sheet sizes 6.8.1 Typical sheet sizes 6.8.2 Tolerances for sheet sizes 6.9 Cut panels 6.9.1 Cut panel sizes 6.9.2 Size tolerances for cut panels 6.9.3 Rectangularity of cut panels Table 7 – Size tolerances for cut panels Table 8 – Rectangularity of cut panels |
15 | 7 Non-electrical properties of the base material after complete removal of the copper foil 7.1 Appearance of the dielectric base material 7.2 Flexural strength 7.3 Flammability Table 9 – Flexural strength requirements |
16 | 7.4 Water absorption 7.5 Measling Table 10 – Flammability requirements Table 11 – Water absorption requirements |
17 | 7.6 Glass transition temperature and cure factor 7.7 Decomposition temperature 7.8 Time to delamination 7.9 Z-axis expansion Table 12 – Measling requirements Table 13 – Glass transition temperature and cure factor requirements Table 14 – Decomposition temperature requirements Table 15 – Time to delamination requirements |
18 | 8 Quality assurance 8.1 Quality system 8.2 Responsibility for inspection 8.3 Qualification inspection 8.4 Quality conformance inspection 8.5 Certificate of conformance Table 16 – Z-axis expansion requirements |
19 | 8.6 Safety data sheet 9 Packaging and marking 10 Ordering information |
20 | Annex A (informative) Engineering information |
22 | Annex B (informative) Common laminate constructions Table B.1 – Thickness |
24 | Annex C (informative) Guideline for qualification and conformance inspection Table C.1 – Qualification and conformance testing |
25 | Bibliography |