BS EN 61515:2016 – TC:2020 Edition

$186.33

Tracked Changes. Mineral insulated metal-sheathed thermocouple cables and thermocouples

Published By Publication Date Number of Pages
BSI 2020 74
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 61515:2016 establishes the requirements for simplex, duplex and triplex mineral-insulated metal-sheathed thermocouple cables and thermocouples, which are intended for use in general industrial applications. The abbreviation MIMS (for ‘mineral-insulated metal-sheathed’) will be used hereafter. It covers thermocouple cables and thermocouples with only base-metal conductors of Types T, J, E, K and N. The specifications in this standard apply to new thermocouple cables and thermocouple units as delivered to the user. They do not apply to the product after use. This second edition cancels and replaces the first edition published in 1995. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: – Duplex and triplex are standardized. – Specification of insulation resistance is revised so that the user can choose the best product to fit for the purpose. – ‘Table 2 Recommended maximum operating temperatures’ in the previous version is expanded significantly including newly developed sheath material and it is moved to Annex C. – Test items and their methods are expanded and a guide table (Table 4) is added for userfriendliness.

PDF Catalog

PDF Pages PDF Title
46 European foreword
Endorsement notice
47 Annex ZA (normative) Normative references to international publications with their corresponding European publications
48 English
CONTENTS
50 FOREWORD
52 INTRODUCTION
53 1 Scope
2 Normative references
3 Terms and definitions
54 4 General principles
4.1 A MIMS thermocouple
55 4.2 Electromotive force
4.3 Materials and their properties
4.3.1 Sheath
4.3.2 Conductors
4.3.3 Insulation materials
4.4 Maximum operating temperature
4.5 Dimensions
4.5.1 Transverse section of MIMS thermocouple cables and thermocouples
56 4.5.2 Transverse section of simplex cable and thermocouple
Figures
Figure 1 – Transverse section of simplex
Tables
Table 1 – Dimensional specifications of simplex
57 4.5.3 Transverse section of duplex cable and thermocouple
Figure 2 – Transverse section of duplex
Table 2 – Dimensional specifications of duplex
58 4.5.4 Transverse section of triplex cable and thermocouple
5 Requirements and verification tests
5.1 General
Figure 3 – Transverse section of triplex
Table 3 – Dimensional specifications of triplex
59 5.2 MIMS thermocouple cables: requirements and verification tests
5.2.1 Structure and mechanical properties
Table 4 – Tests for MIMS thermocouple cables and thermocouples
60 5.2.2 Electrical characteristics and performance
61 Table 5 – Test voltage for dielectric strength
Table 6 – Minimum insulation resistance at ambient temperature (MIMS cables)
62 5.3 MIMS thermocouples: requirements and verification tests
5.3.1 Structure and mechanical properties
Figure 4 – Longitudinal section of a grounded junction
Table 7 – Insulation resistance at elevated temperatures (MIMS cables)
63 Figure 5 – Longitudinal section of an insulated junction
64 5.3.2 Electrical characteristics and performance
65 Table 8 – Minimum insulation resistance at ambient temperature
Table 9 – Insulation resistance at elevated temperatures (MIMS thermocouples)
66 6 Delivery condition for thermocouple cables
7 Packaging
8 Marking
9 Certification
67 Annex A (informative)Alternative adjacent conductor configurations
A.1 General
A.2 Duplex cable and thermocouple
A.3 Triplex cable and thermocouple
Figure A.1 – Alternative adjacent conductor configuration for duplex
68 Figure A.2 – Alternative adjacent conductor configuration for triplex (1)
Figure A.3 – Alternative adjacent conductor configuration for triplex (2)
69 Figure A.4 – Alternative adjacent conductor configuration for triplex (3)
70 Annex B (informative)Mineral insulation material chemical composition
Table B.1 – Example values of recommended magnesia (MgO) – Chemical composition in weight percent
Table B.2 – Example values of recommended alumina (Al2O3) –Chemical composition in weight percent
71 Annex C (informative)Indicative upper temperature limits
Table C.1 – Indicative temperature limits of MIMS thermocouple sheath and conductor combinations
BS EN 61515:2016 - TC