BS EN 61784-3-12:2010

$227.44

Industrial communication networks. Profiles – Functional safety fieldbuses. Additional specifications for CPF 12

Published By Publication Date Number of Pages
BSI 2010 102
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

IEC 61784-3-12:2010 specifies a safety communication layer (services and protocol) based on CPF 12 of IEC 61784-2 and IEC 61158 Type 12. It identifies the principles for functional safety communications defined in IEC 61784-3 that are relevant for this safety communication layer. This bilingual version (2012-02) corresponds to the monolingual English version, published in 2010-06.

PDF Catalog

PDF Pages PDF Title
7 CONTENTS
11 0 Introduction
0.1 General
Figures
Figure 1 ā€“ Relationships of IEC 61784-3 with other standards (machinery)
12 Figure 2 ā€“ Relationships of IEC 61784-3 with other standards (process)
13 0.2 Patent declaration
14 1 Scope
2 Normative references
15 3 Terms, definitions, symbols, abbreviated terms and conventions
3.1 Terms and definitions
20 3.2 Symbols and abbreviated terms
21 3.3 Conventions
4 Overview of FSCP 12/1 (Safety-over-EtherCATā„¢)
Tables
TableĀ 1 ā€“ State machine description elements
22 FigureĀ 3 ā€“ Basic FSCPĀ 12/1 system
23 5 General
5.1 External document providing specifications for the profile
5.2 Safety functional requirements
24 5.3 Safety measures
5.4 Safety communication layer structure
FigureĀ 4 ā€“ FSCPĀ 12/1 software architecture
TableĀ 2 ā€“ Communication errors and detection measures
25 5.5 Relationships with FAL (and DLL, PhL)
6 Safety communication layer services
6.1 FSoE Connection
6.2 FSoE Cycle
26 6.3 FSoE services
FigureĀ 5 ā€“ FSoE Cycle
Figure 6 ā€“ FSCPĀ 12/1 communication structure
27 7 Safety communication layer protocol
7.1 Safety PDU format
FigureĀ 7 ā€“ Safety PDU for CPFĀ 12 embedded in TypeĀ 12 PDU
TableĀ 3 ā€“ General Safety PDU
28 TableĀ 4 ā€“ Shortest Safety PDU
TableĀ 5 ā€“ Safety PDU command
29 TableĀ 6 ā€“ CRC_0 calculation sequence
TableĀ 7 ā€“ CRC_i calculation sequence (i>0)
30 TableĀ 8 ā€“ Example for CRC_0 inheritance
31 TableĀ 9 ā€“ Example for 4 octets of safety data with interchanging of octets 1-4 with 5-8
32 7.2 FSCPĀ 12/1 communication procedure
33 FigureĀ 8 ā€“ FSCPĀ 12/1 node states
34 TableĀ 10 ā€“ Safety Master PDU for 4 octets of safety data with command = Reset after restart (reset connection) or error
TableĀ 11 ā€“ Safety Slave PDU for 4 octets of safety data with command = Reset for acknowledging a Reset command from the FSoE Master
35 TableĀ 12 ā€“ Safety Slave PDU for 4 octets of safety data with command = Reset after restart (reset connection) or error
TableĀ 13 ā€“ Safety Master PDU for 4 octets of safety data with command = Session
36 TableĀ 14 ā€“ Safety Slave PDU for 4 octets of safety data with command = Session
TableĀ 15 ā€“ Safety data transferred in the connection state
37 TableĀ 16 ā€“ Safety Master PDU for 4 octets of safety data in Connection state
TableĀ 17 ā€“ Safety Slave PDU for 4 octets of safety data in Connection state
38 TableĀ 18 ā€“ Safety data transferred in the parameter state
TableĀ 19 ā€“ First Safety Master PDU for 4 octets of safety data in parameter state
39 TableĀ 20 ā€“ First Safety Slave PDU for 4 octets of safety data in parameter state
TableĀ 21 ā€“ Second Safety Master PDU for 4 octets of safety data in parameter state
40 TableĀ 22 ā€“ Second Safety Slave PDU for 4 octets of safety data in parameter state
TableĀ 23 ā€“ Safety Master PDU for 4 octets of ProcessData in data state
41 TableĀ 24 ā€“ Safety Slave PDU for 4 octets of ProcessData in data state
TableĀ 25 ā€“ Safety Master PDU for 4 octets of fail-safe data in data state
42 7.3 Reaction on communication errors
TableĀ 26 ā€“ Safety Slave PDU for 4 octets of fail-safe data in data state
TableĀ 27 ā€“ FSoE communication error
43 7.4 State table for FSoE Master
TableĀ 28 ā€“ FSoE communication error codes
TableĀ 29 ā€“ States of the FSoE Master
44 FigureĀ 9 ā€“ State diagram for FSoE Master
45 TableĀ 30 ā€“ Events in the FSoE Master state table
TableĀ 31 ā€“ Functions in the FSoE Master state table
46 TableĀ 32 ā€“ Variables in the FSoE Master state table
TableĀ 33 ā€“ Macros in the FSoE Master state table
61 7.5 State table for FSoE Slave
TableĀ 34 ā€“ States of the FSoE Slave
62 FigureĀ 10 ā€“ State diagram for FSoE Slave
63 TableĀ 35 ā€“ Events in the FSoE Slave state table
TableĀ 36 ā€“ Functions in the FSoE Slave state table
64 TableĀ 37 ā€“ Variables in the FSoE Slave state table
TableĀ 38 ā€“ Macros in the FSoE Slave state table
84 8 Safety communication layer management
8.1 FSCPĀ 12/1 parameter handling
8.2 FSoE communication parameters
85 9 System requirements
9.1 Indicators and switches
TableĀ 39 ā€“ FSoE Communication parameters
TableĀ 40 ā€“ Indicator States
86 FigureĀ 11 ā€“ Indicator flash rates
TableĀ 41 ā€“ FSoE STATUS indicator states
87 9.2 Installation guidelines
9.3 Safety function response time
FigureĀ 12 ā€“ Components of a safety function
88 FigureĀ 13 ā€“ Calculation of the FSoE Watchdog times for input and output connections
TableĀ 42 ā€“ Definition of times
89 FigureĀ 14 ā€“ Calculation of the worst case safety function response time
90 9.4 Duration of demands
9.5 Constraints for calculation of system characteristics
91 FigureĀ 15 ā€“ Safety PDU embedded in standard PDU
92 9.6 Maintenance
9.7 Safety manual
10 Assessment
FigureĀ 16 ā€“ Residual error rate for 8/16/24 bit safety data and up to 12Ā 144 bit standard data
93 Annex A (informative) Additional information for functional safety communication profiles of CPF 12
98 Annex B (informative) Information for assessment of the functional safety communication profiles of CPF 12
99 Bibliography
BS EN 61784-3-12:2010