BS EN 61788-8:2010

$167.15

Superconductivity – AC loss measurements. Total AC loss measurement of round superconducting wires exposed to a transverse alternating magnetic field at liquid helium temperature by a pickup coil method

Published By Publication Date Number of Pages
BSI 2010 38
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 61788-8:2010 specifies the measurement method of total AC losses by the pickup coil method in composite superconducting wires exposed to a transverse alternating magnetic field. The losses may contain hysteresis, coupling and eddy current losses. The standard method to measure only the hysteresis loss in DC or low-sweep-rate magnetic field is specified in IEC 61788-13. In metallic and oxide round superconducting wires expected to be mainly used for pulsed coil and AC coil applications, AC loss is generated by the application of time-varying magnetic field and/or current. The contribution of the magnetic field to the AC loss is predominant in usual electromagnetic configurations of the coil applications. For the superconducting wires exposed to a transverse alternating magnetic field, the present method can be generally used in measurements of the total AC loss in a wide range of frequency up to the commercial level, 50/60 Hz, at liquid helium temperature. For the superconducting wires with fine filaments, the AC loss measured with the present method can be divided into the hysteresis loss in the individual filaments, the coupling loss among the filaments and the eddy current loss in the normal conducting parts. In cases where the wires do not have a thick outer normal conducting sheath, the main components are the hysteresis loss and the coupling loss by estimating the former part as an extrapolated level of the AC loss per cycle to zero frequency in the region of lower frequency, where the coupling loss per cycle is proportional to the frequency. This second edition cancels and replaces the first edition published in 2003. This edition constitutes a technical revision. The main changes with respect to the previous edition are listed below: – extending the applications of the pickup coil method to the a.c. loss measurements in metallic and oxide superconducting wires with a round cross section at liquid helium temperature, – using the word “uncertainty” for all quantitative (associated with a number) statistical expressions and eliminating the quantitative use of “precision” and “accuracy”. Key words: superconductivity, TC90

PDF Catalog

PDF Pages PDF Title
6 CONTENTS
8 INTRODUCTION
9 1 Scope
2 Normative references
3 Terms and definitions
11 4 Principle
12 5 Apparatus
5.1 Testing apparatus
5.2 Pickup coils
5.3 Compensation circuit
13 6 Specimen preparation
6.1 Coiled specimen
6.2 Specimen coil form
7 Testing conditions
7.1 External applied magnetic field
14 7.2 Setting of the specimen
7.3 Measurement temperature
7.4 Test procedure
15 8 Calculation of results
8.1 Amplitude of applied magnetic field
8.2 Magnetization
16 8.3 Magnetization curve
8.4 AC loss
8.5 Hysteresis loss
8.6 Coupling loss and coupling time constant [5,6]
9 Uncertainty
9.1 General
17 9.2 Uncertainty of measurement apparatus
9.3 Uncertainty of applied field
9.4 Uncertainty of measurement temperature
10 Test report
10.1 Identification of specimen
10.2 Configuration of coiled specimen
18 10.3 Testing conditions
10.4 Results
10.5 Measurement apparatus
19 Figures
Figure 1 – Standard arrangement of the specimen and pickup coils
20 Figure 2 – A typical electrical circuit for AC loss measurement by pickup coils
21 Annex A (informative) Additional information relating to Clauses 1 to 10
23 Annex B (informative) Explanation of AC loss measurement with Poynting’s vector [10]
24 Annex C (informative) Estimation of geometrical error in the pickup coil method
Figure C.1 – Examples of calculated contour line map of the coefficient G
25 Annex D (informative) Recommended method for calibration of magnetization and AC loss
26 Figure D.1 – Evaluation of critical field from magnetization curves
27 Annex E (informative) Coupling loss for various types of applied magnetic field
Figure E.1 – Waveforms of applied magnetic field with a period T = 1/f
28 Annex F (informative) Uncertainty considerations
29 Tables
Table F.1 – Output signals from two nominally identical extensometers
Table F.2 – Mean values of two output signals
Table F.3 – Experimental standard deviations of two output signals
30 Table F.4 – Standard uncertainties of two output signals
Table F.5 – Coefficient of variations of two output signals
33 Annex G (informative) Evaluation of uncertainty in AC loss measurement by pickup coil method [13]
35 Table G.1 – Propagation of relative uncertainty in the pickup coil method (α = 0,5)
36 Bibliography