BS EN 62019:1999+A12:2014
$167.15
Electrical accessories. Circuit-breakers and similar equipment for household use. Auxiliary contact units
Published By | Publication Date | Number of Pages |
BSI | 2014 | 42 |
!This International Standard applies to auxiliary electromechanical contact units associated (or intended to be associated) with circuit-breakers for overcurrent protection, and with residual current operated circuit-breakers with or without integral overcurrent protection for household and similar installations, having a rated voltage not exceeding 440 V a.c. and 250 V d.c., and a rated current not exceeding 10 A.”
NOTE 1 These requirements may also be used as guidance for auxiliary contacts units intended to be assembled with other switching devices for household and similar installations.
NOTE 2 It is recommended that the advice of the manufacturer be sought concerning any application with low level energy appliances (low level values of current and/or voltage.) For low-energy contacts, specific recommendations are given in IEC 60947-5-4.
The object of this standard is to state
-
the characteristics of the auxiliary contact units;
-
their electrical and mechanical requirements with respect to
-
the various duties to be performed;
-
the significance of the rated characteristics and of the markings;
-
the tests to verify the rated characteristics;
-
the functional requirements to be satisfied by the auxiliary contact units with respect to
-
environmental conditions, including those of enclosed equipment;
-
dielectric properties;
-
terminals;
-
safety of use.