Shopping Cart

No products in the cart.

BS EN 62439-5:2010

$189.07

Industrial communication networks. High availability automation networks – Beacon redundancy protocol (BRP)

Published By Publication Date Number of Pages
BSI 2010 46
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

The IEC 62439 series is applicable to high-availability automation networks based on the ISO/IEC 8802-3 (IEEE 802.3) (Ethernet) technology.

This part of the IEC 62439 series specifies a redundancy protocol that is based on the duplication of the network, the redundancy protocol being executed within the end nodes, as opposed to a redundancy protocol built in the switches. Fast error detection is provided by two beacon nodes, the switchover decision is taken in every node individually. The cross-network connection capability enables single attached end nodes to be connected on either of the two networks.

PDF Catalog

PDF Pages PDF Title
7 CONTENTS
9 INTRODUCTION
10 1 Scope
2 Normative references
3 Terms, definitions, abbreviations, acronyms, and conventions
3.1 Terms and definitions
11 3.2 Abbreviations and acronyms
3.3 Conventions
4 BRP overview
5 BRP principle of operation
5.1 General
5.2 Network topology
12 Figures
FigureĀ 1 ā€“ BRP star network example
FigureĀ 2 ā€“ BRP linear network example
13 5.3 Network components
FigureĀ 3 ā€“ BRP ring network example
14 5.4 Rapid reconfiguration of network traffic
6 BRP stack and fault detection features
FigureĀ 4 ā€“ BRP stack architecture
16 7 BRP protocol specification
7.1 MAC addresses
7.2 EtherType
7.3 Fault detection mechanisms
7.4 End node state diagram
17 FigureĀ 5 ā€“ BRP state diagram of end node
19 Tables
TableĀ 1 ā€“ BRP end node flags
20 TableĀ 2 ā€“ BRP end node state transition table
24 7.5 Beacon end node state diagram
FigureĀ 6 ā€“ BRP state diagram for beacon end node
26 TableĀ 3 ā€“ BRP beacon end node flags
27 TableĀ 4 ā€“ BRP beacon end node state transition table
30 8 BRP message structure
8.1 General
31 8.2 ISO/IEC 8802-3 (IEEE 802.3) tagged frame header
8.3 Beacon message
8.4 Learning_Update message
TableĀ 5 ā€“ BRP common header with ISO/IECĀ 8802 3 (IEEEĀ 802.3) tagged frame format
TableĀ 6 ā€“ BRP beacon message format
TableĀ 7 ā€“ BRP Learning_Update message format
32 8.5 Failure_Notify message
8.6 Path_Check_Request message
8.7 Path_Check_Response message
9 BRP fault recovery time
TableĀ 8 ā€“ BRP Failure_Notify message format
TableĀ 9 ā€“ BRP Path_Check_Request message format
TableĀ 10 ā€“ BRP Path_Check_Response message format
33 10 BRP service definition
10.1 Supported services
34 10.2 Common service parameters
10.3 Set_Node_Parameters service
35 TableĀ 11 ā€“ BRP Set_Node_Parameters service parameters
36 10.4 Get_Node_Parameters service
37 TableĀ 12 ā€“ BRP Get_Node_Parameters service parameters
38 10.5 Add_Node_Receive_Parameters service
39 TableĀ 13 ā€“ BRP Add_Node_Receive_Parameters service parameters
40 10.6 Remove_Node_Receive_Parameters service
TableĀ 14 ā€“ BRP Remove_Node_Receive_Parameters service parameters
41 10.7 Get_Node_Status service
TableĀ 15 ā€“ BRP Get_Node_Status service parameters
42 11 BRP Management Information Base (MIB)
44 Bibliography
BS EN 62439-5:2010
$189.07