BS EN IEC 60068-2-14:2023 – TC
$217.84
Tracked Changes. Environmental testing – Tests. Test N: Change of temperature
Published By | Publication Date | Number of Pages |
BSI | 2023 | 87 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 30480461 |
47 | A-30445529 |
48 | undefined |
51 | Annex ZA (normative)Normative references to international publicationswith their corresponding European publications |
52 | English CONTENTS |
54 | FOREWORD |
56 | INTRODUCTION |
57 | 1 Scope 2 Normative references 3 Terms and definitions |
58 | 4 Symbols 5 General 5.1 Field conditions of changing temperature |
59 | 5.2 Design of tests with temperature change 5.3 Test parameters |
60 | 5.4 Purpose and choice of the tests 5.5 Choice of the exposure time to each conditioning temperature |
61 | 5.6 Choice of the duration of the transfer time t2 5.7 Applicability limits of change of temperature tests Figures Figure 1 – Determination of the exposure time t1 of the specimen to each conditioning temperature |
62 | 6 Initial and final measurements 6.1 General 6.2 Initial measurements 6.3 Final measurements 7 Test Na: Rapid change of temperature 7.1 General description of the test 7.2 Testing procedure 7.2.1 Testing chamber |
63 | Figure 2 – Schematic representation of examples of thermal test cabinets and test procedure with two separate test chambers |
64 | Figure 3 – Schematic representation of examples of thermal test cabinets with one test chamber |
65 | 7.2.2 Mounting or supporting of the test specimen 7.2.3 Severities Figure 4 – Possibility of condensation during rapid temperature change Figure 5 – Possibility of condensation during transfer of the specimen |
66 | 7.2.4 Preconditioning Figure 6 – Increased severity of Test Na |
67 | 7.2.5 Test cycle Figure 7 – Na test cycle, one-chamber method |
69 | 7.3 Recovery 8 Test Nb: Change of temperature with specified rate of change 8.1 General description of the test Figure 8 – Na test cycle, two-chamber method |
70 | 8.2 Testing procedure 8.2.1 Testing chamber 8.2.2 Mounting or supporting structure of the test specimen 8.2.3 Severities |
71 | 8.2.4 Tolerance |
72 | 8.2.5 Preconditioning 8.3 Test cycle Figure 9 – Tolerance for fluctuation of test temperatures |
73 | 8.4 Recovery Figure 10 – Nb test cycle Figure 11 – Test times for intermediate operation of specimens |
74 | 9 Test Nc: Rapid change of temperature, two-fluid-bath method 9.1 General description of the test 9.2 Testing procedure 9.2.1 Testing equipment 9.2.2 Severities 9.2.3 Conditioning |
75 | 9.3 Test cycle 9.4 Recovery Figure 12 – Nc test cycle |
76 | 10 Information to be given in the test report |
77 | Annex A (informative) Potential consequences of improper severities Figure A.1 – Delayed temperature change of the specimen |
78 | Annex B (informative) Thermal responsiveness of different materials and geometries Figure B.1 – Rate of temperature change of specimen with differing thermal responsiveness |
79 | Annex C (normative) Auxiliary table with exemplary temperature tolerances ±σT for preferred combinations of high and low conditioning temperatures and rates of temperature change (Test Nb) |
80 | Figure C.1 – Tolerance for fluctuation of test temperatures for exemplary test parameters |
81 | Tables Table C.1 – Applicable temperature tolerances ±σT in K for preferred combinations of high and low conditioning temperatures and rates of temperature change dTR |
85 | Bibliography |