Shopping Cart

No products in the cart.

BS EN IEC 62129-3:2019

$142.49

Calibration of wavelength/optical frequency measurement instruments – Optical frequency meters internally referenced to a frequency comb

Published By Publication Date Number of Pages
BSI 2019 28
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 62129-3:2019 describes the calibration of optical frequency meters using an optical frequency comb as an internal reference. It is applicable to instruments measuring the optical frequency emitted from sources that are typical for the fibre-optic communications industry. It is assumed that the optical radiation will be coupled to the optical frequency meter by a single-mode optical fibre. This document is part of the IEC 62129 series on the calibration of wavelength/optical frequency measurement instruments. Refer to IEC 62129­1 [3] for the calibration of optical spectrum analyzers, and refer to IEC 62129-2 [4] for calibration of Michelson interferometer single wavelength meters. This first edition cancels and replaces IEC TS 62129-3, published in 2014. This edition includes the following significant technical changes with respect to the previous edition: a) text has been added to 5.2.3 about calibration at a second optical frequency; b) Annex D is now normative; c) Subclause 4.2 has been improved; d) measurement method of frequency has been moved to Annex B; e) example of optical frequency comb has been moved to Annex C; f) frequency-dependence uncertainty has been moved to Annex D. Keywords: calibration of optical frequency meters

PDF Catalog

PDF Pages PDF Title
2 National foreword
5 Annex ZA(normative)Normative references to international publicationswith their corresponding European publications
7 English
CONTENTS
8 FOREWORD
11 1 Scope
2 Normative references
3 Terms and definitions
13 4 Calibration test requirements
4.1 Organization
4.2 Traceability
4.3 Preparation
4.4 Reference calibration conditions
5 Optical frequency calibration
5.1 Establishing the calibration conditions
14 5.2 Calibration procedure
5.2.1 General
5.2.2 Measurement configuration
Figures
Figure 1 – Optical frequency meter measurement using a reference source
15 5.2.3 Detailed procedure
5.3 Calibration uncertainty
Figure 2 – Optical frequency meter measurementusing a reference optical frequency meter
16 5.4 Reporting the results
6 Absolute power calibration
17 Annex A (normative)Mathematical basis for measurement uncertainty calculations
A.1 General
A.2 Type A evaluation of uncertainty
A.3 Type B evaluation of uncertainty
18 A.4 Determining the combined standard uncertainty
19 A.5 Reporting
20 Annex B (informative)Measurement method for the frequency of a stabilized laserwith an optical frequency comb
Figure B.1 – Schematic configuration of optical frequencymeasurement technique using an optical comb
21 Figure B.2 – Optical spectra of lasers and optical frequency combs
22 Annex C (informative)Examples of stabilized optical frequency comb source
C.1 Method A (pump pulse source and nonlinear optical effect)
C.2 Method B (stabilized laser and electro-optical modulator)
Figure C.1 – Pump pulse source and nonlinear optical effect
23 Figure C.2 – Electro-optical modulator type comb source
24 Annex D (normative)Frequency-dependence of uncertainty
25 Bibliography
BS EN IEC 62129-3:2019
$142.49